DGEA-...-YSR
Festo DGEA-...-YSR 2018-12b English
4
2
Method of operation and use
The DGEA-...-YSR has been designed for fastening shock absorbers on the canti
lever axis type DGEA-... in the area of the stroke reserve.
It is not intended as a fixed stop in the positioning range of the cantilever axis.
3
Conditions of use
When fitting to cantilever axes which are already set:
S
Check whether a speed limitation or a mass modification to the DGEA-... is
necessary.
The use of the shock absorber causes an additional torque on the cantilever
arm.
The DGEA-... can only be operated reliably (see also the technical specifica
tions for the shock absorber) if the maximum loading limits are not exceeded.
4
Fitting
1. Position the cantilever arm in a mechan
ical end position (W).
2. Push the cantilever arm out of the end
position by the dimension Y.
DGEA-...
Dimension Y [mm]
18
Shock absorber stroke
+13.5 mm
25
Shock absorber stroke
+2 mm
40
Shock absorber stroke
+2 mm
(w)
(w)
y
Fig. 2