Adjust the guides of the payload and DGC-HD so that they are exactly parallel.
You will then avoid overloading the guide and increased wear.
6.1.3
Installation of accessories
If proximity sensors are used:
•
Use:
•
Inductive proximity sensor with switch lug
aC
(
è
assembly instructions for the accessories
used) in the slot
aA
or with a mounting bracket
aD
in the slot
9
•
Magnetic proximity switches in the slot
aA
.
Mounting alternatives:
Fig. 7 Mounting in the slot
Fig. 8 Mounting via mounting bracket
To protect the end positions:
•
Use an emergency buffer or shock absorber (
è
assembly instructions for the accessories used).
To avoid contamination:
•
Use slot covers in all unused slots.
6.2
Pneumatic installation
For installation in a vertical or sloping position:
Installation
9
Festo — DGC-HD — 2018-10b