![Festo CPX-E-CEC EP Series Instructions Manual Download Page 6](http://html1.mh-extra.com/html/festo/cpx-e-cec-ep-series/cpx-e-cec-ep-series_instructions-manual_2283165006.webp)
Power supply
Operating power supply
U
EL/SEN
[V DC]
24
_
25%
Intrinsic current consumption
at nominal operating voltage
24 V from U
EL/SEN
[mA]
Typ. 150
Reverse polarity protection
24 V U
EL/SEN
against
0 V U
EL/SEN
Yes
Mains buffering time
[ms]
20
Tab. 19 Power Supply
Network-specific data
Protocol
EtherNet/IP
1)
, EtherCAT
Transmission rate
[Mbps]
10/100 (full duplex/half duplex)
Crossover detection
Auto-MDI/MDI-X
Maximum cable length per
segment
[m]
100
2)
Cable specification
Cable type
Ethernet twisted pair cable, shielded
Transmission class
Category Cat 5/Cat 5e (link class)
Cable diameter
[mm]
6 … 8
Wire cross section
[mm
2
]
0.14 … …0.75; 22 AWG
3)
1) based on the Ethernet protocol IEEE 802.3
2) at a transmission rate of 100 Mbps
3) required for maximum connection length between network participants
Tab. 20 Network-specific Data
13.2
Technical Data UL/CSA Certification
Ambient conditions UL/CSA
Pollution degree
3
Installation site
for indoor use only
Max. installation height
[m]
2000
Tab. 21 Ambient Conditions UL/CSA
Ambient temperature
Mounting position
Vertical
Horizontal
Operating power supply U
EL/SEN
via XD
Ambient temperature, max. current rating
of terminal strip
£
4 A
[°C]
–5 … +60
–5 … +50
Ambient temperature, max. current rating
of terminal strip
>
4 … 8 A
[°C]
–5 … +50
–5 … +40
Operating voltage U
EL/SEN
with feed via both connections [XD]
1)
Ambient temperature, max. current rating
of terminal strip
>
4 … 8 A
[°C]
–5 … +60
–5 … +50
1) see chapter 'Product design' or 'Connection elements'
Tab. 22 Ambient temperature ranges