CMSX-...-C-U-F1-...
16
Festo – CMSX-...-C-U-F1-... – 1506a English
6.1.2
CMSX-SE-... (linear)
1. Close process valve.
2. Switch off the compressed air and the power
supply.
3. Secure the mounting adapter
1
to the
positioner.
– 4 housing screws
3
– Tightening torque 1.5 Nm ± 20 %.
4. Secure the housing (flange socket)
5
to the
linear drive
6
.
– 4 mounting screws
4
– Tightening torque
è
5. Secure the mounting adapter
1
to the housing
(flange socket)
5
.
4 mounting screws
4
Tightening torque 1.5 Nm ± 20 %.
6. Secure the positioner with mounting adapter to
the housing (flange socket)
– 4 mounting screws
2
– Tightening torque 3 Nm ± 20 %.
Fig. 13
Mechanical installation CMSX-SE-...
(linear)
1
2
4
5
6
3
Design
DFPI-100-...-E-P-G2 to
DFPI-160-...-E-P-G2
DFPI-200-...-E-P-G2 to
DFPI-320-...-E-P-G2
Tightening torque
[Nm]
2.7 ± 10 %
6 ± 10 %
Tab. 2