Digital inputs at [X1A] without safety inputs
Min. input current with
high-level (I
H min
)
[mA]
5
Max. input current with
low-level (I
L max
)
[mA]
15
Min. input current in
transition range (I
T min
)
[mA]
1.5
Data for inputs CAP0, CAP1
Delay time in the hard-
ware
[µs]
<
2
Min. permissible pulse
length (high or low)
[µs]
10
Time resolution/accur-
acy (high or low)
[µs]
<
1
Tolerance for low test
pulses
No
Data for remaining inputs
Delay time in the hard-
ware
[µs]
<
200
Min. permissible pulse
length (high or low)
[µs]
1000
Tolerance for low test
pulses
[ms]
1
Min. period length
between test pulses
[ms]
100
Tab. 120 Digital inputs at [X1A] without safety inputs