During operation, make sure that no danger is caused by the controlled
peripheral equipment.
Switching on
1. Switch on the operating voltage of the product via the power pack.
2. Start the CheckKon software to display and set the system parameters.
3. If necessary, start the transport device manually.
Fig. 5: STOP status
–
Readiness to operate is signaled by the STOP status.
–
The IP address shows the current IP address of the product
(factory setting: 192.168.2.20).
–
CHB-C-N firmware version number (3.6.4.0)
–
(Hash value of firmware version 0f9102550)
Additional steps in preparation for commissioning can be found in the
è
CHB-C-N
description.
8
Diagnostics and fault clearance
Malfunctions are displayed on the product as follows:
–
The product automatically switches to the STOP state.
–
The illuminated pushbuttons flash.
–
The display shows the error code including an explanation in English. An over-
view of the error types
è
Description CHB-CN.
Fig. 6: Example of fault message Error 5
Example:
–
ERROR error number (5)
–
The error description (Material jam) provides a brief textual description for the
corresponding error number and information concerning remedial measures.
Button
Status
Meaning
Start/Stop
Flashes red
Error message/warning
Status/Teach
Flashes yellow
Tab. 10: Error display
The product cannot be restarted until the fault has been eliminated:
1. Eliminate the cause of malfunction.
2. Acknowledge error message: press the Start/Stop button.
3. Start the product: press the start/stop button.
Details regarding the error codes and instructions on eliminating the errors can be
found in the
è
CHB-C-N description.
Malfunctions are also signaled at the PLC connection via A/17 (error) and, if
necessary, A/23 (warning).
9
Repair
The prism module can be replaced if it is damaged.
Additional information
è
Description CHB-C-N.
10
Technical data
CHB-C-N
Ambient temperature
[°C]
5 … 50 with 1 A load
5 … 45 with 3 A load
Storage temperature
[°C]
–20 … +70
Ambient conditions
Dry, screened from extreme external light sources,
cleanest possible ambient air
Protection against electric
shock
PELV (Protective Extra-Low Voltage)
CE marking
In accordance with EU EMC Directive
See declaration of conformity
Vibration resistance
in accordance with
EN 60068-2-6
Severity level 2
Shock resistance in accord-
ance with EN 60068-2-27
Severity level 2
Degree of protection in
accordance with EN 60529
IP64
(plug connector inserted or provided with protective
cap)
Max. permissible cable lengths
Power supply
[m]
30
I/O signals
[m]
30
Ethernet
[m]
70
Electrical data
Nominal operating voltage
[V DC]
24
Permissible voltage fluctua-
tions
[%]
–15/+20
Current consumption with
load-free outputs
[mA]
400
Internal fuse protection
[A]
4 (fuse)
Interfaces
Connection for encoder
According to RS485 specification
Ethernet connection
Ethernet interface 100 MBit/s
Dimensions
Length/width/height
(without plug connector)
[mm]
164/60/241
Inside passage of the optical
channel
[mm]
59.2
Inside height of the optical
channel
[mm]
40
Electrical properties of the I/O signals
Outputs
All outputs electronically limited to max. 700 mA
Max. resultant current at
“PLC” connection
[A]
0.9
Max. total current at the con-
nections Actuator, Buffer
[A]
1.9
Max. resultant current of all
outputs
[A]
3
Camera and lighting
Resolution
[pixels]/
[µm]
2048/14 × 14
Line rate
[Hz]
1000 … 8500
Properties of conveyed parts
Component range
Rotationally symmetrical parts and pre-oriented parts
of any shape
Min. part length
[mm]
1
Max. part length
Dependent on belt speed and required resolution
Part diameter
[mm]
0.5 … 25
Tab. 11: Technical data