4
Commissioning
30
Festo – GDCP-CMMS-AS-G2-S1-EN – 1306NH – English
4
Commissioning
Note
The term “commissioning” does not mean the first intended use by the end customer. It
refers to commissioning by the manufacturer during setup of the machine.
Note
Loss of the safety function!
Lack of the safety function can result in serious, irreversible injuries, e.g. due to uncon-
trolled movements of the connected actuator technology.
•
Place motor controller in operation only when all safeguarding, including the safety
function, has been installed and checked for functionality.
•
The safety function must be tested and a corresponding validation procedure carried
out prior to the intended use
Section 4.2.
Incorrect wiring or the use of incorrect external components, which have not been selec-
ted in accordance with the safety category, can result in a loss of the safety function.
•
Carry out a risk assessment for your application and select the circuitry and components accord-
ingly.
•
Observe the examples
Sections 2.3 and 2.4.
4.1
Prior to commissioning
Carry out the following steps in preparation for commissioning:
1. Make sure the motor controller is correctly mounted (
Section 3.1).
2. Check the electrical installation (connecting cable, pin allocation
Section 3.2). Are all protective
earth conductors connected?