A. Technical appendix
A-5
Festo P.BE-MPA-EN en 1108e
Note
MPA-S valve terminal with multi-pin plug connection:
– The maximum number of sub-bases that can be
configured corresponds to the number of addresses
available. The maximum number of solenoid coils which
can be actuated is limited by the multi-pin plug
connection to 24 addresses.
MPA-S valve terminal with CPX terminal:
– A maximum 16 sub-bases (MPA-S with electric
supply plate) or 8 sub-bases (MPA-S without electric
supply plate) are permitted.
MPA-S valve terminal with CPX terminal or multi-pin plug
connection:
– For wall mounting, with 7 or more sub-bases, additional
fasteners (wall brackets) must be mounted after every 2
to max. 4 sub-bases.