4. Commissioning
4-12
Festo P.BE-MPA-EN en 1108e
Note
The detenting actuation of the manual override is only
possible if a manual override cap is not fitted.
Detenting actuation of the manual override (manual reset)
Operation
Valve response
•
Use a screwdriver (max. blade
width 3 mm) to press down the
plunger of the manual override
until the valve switches.
•
Then turn the plunger in a
clockwise direction one fourth of a
turn.
The pilot valve switches and controls
the power valve in the switching
position.
•
Remove the screwdriver.
The valve maintains the switching
position.
•
With the screwdriver, turn the
plunger one fourth of a turn
anti-clockwise.
•
Remove the screwdriver.
The spring force presses the plunger
of the HHN into the basic setting.
The pilot valve returns to its neutral
position and thus also the power
valve (not for impulse valve,
ident. code J).
Tab. 4/5:
Turning/locking actuation of the manual override
Summary of Contents for 530411
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 1108e ...
Page 16: ...Contents and general instructions XIV Festo P BE MPA EN en 1108e ...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 1108e Chapter 1 Summary of components ...
Page 59: ...Fitting 2 1 Festo P BE MPA EN en 1108e Chapter 2 Fitting ...
Page 73: ...Installation 3 1 Festo P BE MPA EN en 1108e Chapter 3 Installation ...
Page 108: ...3 Installation 3 36 Festo P BE MPA EN en 1108e ...
Page 109: ...Commissioning 4 1 Festo P BE MPA EN en 1108e Chapter 4 Commissioning ...
Page 172: ...5 Maintenance and conversion 5 42 Festo P BE MPA EN en 1108e ...
Page 173: ...Technical appendix A 1 Festo P BE MPA EN en 1108e Appendix A Technical appendix ...
Page 209: ...Index C 1 Festo P BE MPA EN en 1108e Appendix C Index ...
Page 210: ...C Index C 2 Festo P BE MPA EN en 1108e Contents C Index C 1 ...