4. Commissioning
4-22
Festo P.BE-MPA-EN en 1108e
4.7.2
Operating states of the pneumatic system
The following conditions should be fulfilled, in order that the
desired pneumatic operating states listed below can be
achieved:
Desired
pneumatic
operating status
Prerequisites
Comment
Zero-leakage
– Tubing connected with care
– Regulated pilot air supply
—
Fast reaction
Sufficient pressure supply by means
of pressure supply modules
Exhaust the MPA-S valve terminal via
all exhaust plates or flat plate
silencer
Trouble-free
Non-return valves in common
exhaust line
This applies when several systems
with centrally ducted exhaust are
used
Two or more
pressure zones
– Limiting the pressure zones by
means of isolating seals with
blocked channels
– Appropriate number of pneumatic
air supply plates for supplying the
different pressure zones.
Subsequent conversion possible
(see Chapter 5)
Vacuum or
low-pressure
operation
Externally supplied regulated pilot
air supply (3 … 8 bar)
Vacuum/Low pressure operation not
with 2x2/2- and 2x3/2-way valves
(Ident. code D, I, H, K, N)
EMERGENCY STOP of
pressure zones
Guaranteeing the controller function
for the pilot air supply despite the
overall supply being switched off
The controller regulates the pilot air
supply to all the valve plates on an
MPA-S valve terminal
Slow start-up after
EMERGENCY STOP
If control signals are present, the
pilot air supply must have a pressure
of 3 ... 8 bar immediately after being
switched on
Tab. 4/11:
Pneumatic operating states
Summary of Contents for 530411
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 1108e ...
Page 16: ...Contents and general instructions XIV Festo P BE MPA EN en 1108e ...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 1108e Chapter 1 Summary of components ...
Page 59: ...Fitting 2 1 Festo P BE MPA EN en 1108e Chapter 2 Fitting ...
Page 73: ...Installation 3 1 Festo P BE MPA EN en 1108e Chapter 3 Installation ...
Page 108: ...3 Installation 3 36 Festo P BE MPA EN en 1108e ...
Page 109: ...Commissioning 4 1 Festo P BE MPA EN en 1108e Chapter 4 Commissioning ...
Page 172: ...5 Maintenance and conversion 5 42 Festo P BE MPA EN en 1108e ...
Page 173: ...Technical appendix A 1 Festo P BE MPA EN en 1108e Appendix A Technical appendix ...
Page 209: ...Index C 1 Festo P BE MPA EN en 1108e Appendix C Index ...
Page 210: ...C Index C 2 Festo P BE MPA EN en 1108e Contents C Index C 1 ...