F) CHRONOGRAPH RESET (INCL. AFTER REPLACING BATTERY)
This procedure should be performed when the chronograph second hand does not return to zero position after the
chronograph has been reset, and including after the battery has been replaced.
1. Pull the crown out to the 2nd position.
2. Press button “A” to set the chronograph second hand to zero position. The chronograph hand can be advanced by
continuously pressing button “A”.
* The chronograph hour and minutes hands are syncronized with chronograph second hand.
* The chronograph second hand can be advanced one scale by pressing button “A” once.
* The chronograph second hand can be advanced rapidly by continuously pressing button “A”.
3. Once the hand have been reset to zero position, push the crown back to the normal position.
* Do not return crown to normal position while chronograph second hand returns to 12:00 (ZERO) position.
Hand stops on the way when crown is returned to normal position and these positions are recognize as 12:00 (ZERO)
position.