OMNIA S 3.2
Order
Port
Code
Assembly unit
Note
22
CN11
1
SL1
Reserved
/
2
SL2
3
H
Room thermostat input (high voltage)
2
4
C
15
L1
5
1ON
SV1 (3-way diverter valve) plant / DHW
B
6
1OFF
16
N
7
2ON
SV2 (3-way valve) heat / cool
2
8
2OFF
17
N
9
P_c
Zone2 pump
2
21
N
10
P_o
Outside circulation pump / zone 1 pump
2
22
N
11
P_s
Solar panel pump
2
23
N
12
P_d
DHW boiler recirculation pump
2
24
N
13
TBH
DHW electric heater
2
16
N
14
IBH1
Internal backup heater 1
B
17
N
18
N
SV3 mixing (3-way valve zone 2)
2
19
3ON
20
3OFF
23
CN30
1
A
Reserved
/
2
B
3
X
4
Y
5
E
6
P
3 Wires for connection with outdoor unit
/
7
Q
8
E
9
H1
Reserved
/
10
H2
24
CN7
26
R2
Compressor run (the contact is closed when the compresor is working)
1
30
R1
31
DFT2
Defrost run (the contact is closed when the defrost is active)
1
32
DFT1
25
HT
Reserved
2
29
N
27
AHS1
Gas boiler (the contact is closed when the gas boiler is request)
1
28
AHS2
25
CN2
TBH_FB
Port for automatic circ. breaker of TBH (shorted in default)
/
26
CN1
IBH1/2_FB
Port for automatic circ. breaker of IBH (shorted in default)
/
27
CN22
IBH1
Control port for internal backup heater 1
/
IBH2
Reserved
/
TBH
Control port for DHW boiler electrical heater
/
28
CN41
HEAT8
Reserved
/
29
CN40
HEAT7
Reserved
/
30
CN42
HEAT6
Reserved
/
31
CN29
HEAT5
Reserved
/
NOTES
:
A
: With accessory Temperature Probe. All these temp. probes can be used or not as a function of the type of the plant served by the unit.
B
: Internal connections, it means that these terminals are used for the management of the indoor unit.
1
:
Dry contact without voltage.
2
:
Port provide 220-240VAC voltage. If the current of load is <0.2A, load can connect to the port directly. If the current of load is >=0.2A, the AC contactor is required to supply for the load.
Voltage
220-240VAC
Maximum running current (A)
0.2
Wiring size (mm
2
)
0.75
Connect the cable to the appropriate terminals as shown in the following pictures.
Fix the cable reliably and provide to pass the cable through the appropriate cable gland (refer to “dimensional data and connections” on page 21.