Cod. 3541V950 - Rev. 00 - 05/2021
OMNIA S 3.2
Indoor unit technical data
10
16
16T
UM
Power supply
220/240-1-50
380/415-3-50
V-ph-Hz
Heat exchanger type
Stainless steel brazed plates
-
Pump type
Electronic circulator (8 mca)
Electronic circulator (9 mca)
-
System expansion tank volume
10
l
System safety water valve set
3
bar
System water connections
1” GAS F
-
DHW water connections
3/4” GAS F
-
Hydraulic fittings / liquid line ***
3/8” SAE / Ø 9,52
-
Hydraulic fittings / gas line
5/8” SAE / Ø 15,88
-
Minimum plant water content
15
25
l
DHW boiler - minimum surface of the coil
(minimum / recommended)
steel
1,4 / 2,5
1,75 / 4,0
m
2
enamel
1,7 / 3,0
2,5 / 5,6
m
2
System electric heater
3
6
kW
SWL - Sound power level
42
42
42
42
43
43
43
43
43
43
dB(A)
Max current input
14
10
A
Net weight
34
36
37
kg
***
For matching with external units mod. 4-6 a reduction fitting from 3/8 ”SAE to 1/4” SAE is provided for liquid line Ø 6.35.
3.2 ERP data
NOTA:
Declared according to
European regulation 811/2013
. The values are referred to units without options and accessories.
Models
4
6
8
10
12
14
16
12T
14T
16T
UM
Seasonal space
heating energy
efficiency class
low temperature (water outlet at 35°C)
191
195
205
204
189
185
182
189
185
182
ηs (%)
A+++
class
medium temperature (water at 55°C)
129
138
131
136
135
135
133
135
135
133
ηs (%)
A++
class
SCOP
low temperature (water outlet at 35°C)
4,85
4,95
5,21
5,19
4,81
4,72
4,62
4,81
4,72
4,62
W/W
medium temperature (water at 55°C)
3,31
3,52
3,36
3,49
3,45
3,47
3,41
3,45
3,47
3,41
W/W
SEER
water at 7°C
4,99
5,34
5,83
5,98
4,89
4,86
4,69
4,86
4,83
4,67
W/W
water at 18°C
7,77
8,21
8,95
8,78
7,10
6,90
6,75
7,04
6,85
6,71
W/W
3.3 Operating limits heat pump
-
-
-
-
-
-
NOTE FOR DHW MODE:
leaving water temperature is the tem-
perature of the water produced by the unit and not the DHW tem-
perature available to the user; the DHW temperature is in fact a
function of this parameter and of the coil surface of the DHW boiler.
Operation range by heat pump with
possible limitation and protection.
Leaving water temperature °C
Leaving water temperature °C
Outside temperature °C
Outside temperature °C
DHW MODE
HEATING MODE
Leaving water temperature °C
Outside temperature °C
COOLING MODE
With IBH (system electric heater) installed.
With IBH (system electric heater) installed.
Operation range by heat pump with possible limita-
tion and protection.
Operation range by heat pump with possible limita-
tion and protection.
Maximum inlet water temperature line for heat
pump operation.
Maximum inlet water temperature line for heat
pump operation.