BLUEHELIX B S 32 K 100
5.2 Water circuit
fig. 28 - Water circuit
5.3 Diagrams
Circulating pump head / pressure losses
fig. 29 - Circulating pump head / Pressure losses BLUEHELIX B S 32 K 100
A =
Boiler pressure losses -
B =
Circulating pump min. speed -
C =
Circulating pump
max. speed
5.4 Technical data table
The column on the right gives the abbreviation used on the technical data plate.
278
193
32
154
36
114
40
180
233
8
192
9
186
10
14b
95
56
11
241
74
14a
0
1
2
3
4
5
6
7
0
500
1.000
1.500
2.000
Q
[l/h]
H
[m H
2
O]
A
C
B
Data
Unit
BLUEHELIX B S 32 K 100
Max. heating capacity
kW
29.5
(Q)
Min. heating capacity
kW
6.7
(Q)
Max. Heat Output in heating (80/60°C)
kW
28.9
(P)
Min. Heat Output in heating (80/60°C)
kW
6.6
(P)
Max. Heat Output in heating (50/30°C)
kW
31.3
Min. Heat Output in heating (50/30°C)
kW
7.2
Max. heating capacity in hot water production
kW
32.0
Min. heating capacity in hot water production
kW
6.7
Max. Heat Output in hot water production
kW
31.4
Min. Heat Output in hot water production
kW
6.6
Efficiency Pmax (80-60°C)
%
98.
Efficiency Pmin (80-60°C)
%
97.8
Efficiency Pmax (50-30°C)
%
106.1
Efficiency Pmin (50-30°C)
%
107.5
Efficiency 30%
%
10
.8
NOx emission class
-
5
(NOx)
Gas supply pressure G20
mbar
20
Max. gas delivery G20
m
3
/h
3.3
Min. gas delivery G20
m
3
/h
0.71
CO
2
max. G20
%
9.
0
CO
2
min. G20
%
8.70
Gas supply pressure G31
mbar
37
Max. gas delivery G31
kg/h
2.
Min. gas delivery G31
kg/h
0.52
CO
2
max. G31
%
10.70
CO
2
min. G31
%
9.80
Max. working pressure in heating
bar
3
(PMS)
Min. working pressure in heating
bar
0.8
Max. heating temperature
°C
90
(tmax)
Heating water content
litres
Heating expansion tank capacity
litres
Heating expansion tank prefilling pressure
bar
0.8
Max. working pressure in hot water production
bar
9
(PMW)
Min. working pressure in hot water production
bar
0,3
DHW content
litres
100
DHW expansion tank capacity
litres
3
DHW expansion tank prefilling pressure
bar
3
DHW flow rate
'
t 30°C
l/10min
27
DHW flow rate
'
t 30°C
l/h
1000
(D)
Protection rating
IP
X5D
Power supply voltage
V/Hz
230V/50Hz
Electrical power input
W
Empty weight
kg
86
Type of unit
C13-C23-C33-C43-C53-C63-C83-B23-B33
PIN CE
0461CM0988
44
EN
cod. 3541G574 - Rev. 00 - 11/2018