Parameter modification menu [TSP]
Press the
heating
buttons to scroll the list, press the button
to display the value To modify,
press the
DHW
, buttons, confirm with the button
or cancel with the button
.
Table 10- Transparent Parameters Table
Index
Description
Range
Default
b01
Boiler type selection
2
= HEATING ONLY (also with OPTIONAL HOT WATER TANK)
2
b02
Boiler type
1
=
18 H
2
=
28 H
3
=
34 H
1
= BLUEHELIX HITECH RRT
18 H
2
= BLUEHELIX HITECH RRT
28 H
3
= BLUEHELIX HITECH RRT
34 H
b03
Gas type
0
= Natural gas
1
= Liquefied gas
2
= Propane-air
0
b04
System water pressure protection selec-
tion
0
= Pressure switch
1
= Pressure transducer
1
b05
Summer/Winter mode
0
= WINTER - SUMMER - OFF
1
= WINTER - OFF
0 = Enabled
b06
Variable input contact operation selection
0
= Flowmeter exclusion
1
= System thermostat
2
= Second room therm.
3
= Warning/Alert
4
= Safety thermostat
2
b07
Relay card LC32 selection
0
= External gas valve
1
= Alarm
2
= System filling solenoid valve
3
= Legionella pump
4
= Second heating pump
5
= Alarm2
6
= Burner lit
7
= Frost protection On
0
b08
Not implemented
--
24
b09
Fault 20 status selection
0
= Deactivated
1
= Enabled (only for versions with pressure transducer)
0
b10
Not implemented
--
--
b11
Hot water tank preparation
0
= Fixed primary (P44)
1
= Linked to DHW Setpoint (P51)
0
b12
Hot water tank priority
0 ÷ 255 min
30
b13
Heating priority
0 ÷ 255 min
15
b14
DHW factor (not used)
0 - 1
0
b15
Not implemented
--
3
b16
Not implemented
--
--
b17
Not implemented
--
--
b18
DHW mode activation flow rate (not
used)
0-100 l/min/10
25
b19
DHW mode deactivation flow rate (not
used)
0-100 l/min/10
20
b20
Flue material selection
0
= Standard
1
= PVC
2
= CPVC
0
b21
Not implemented
--
--
b22
Not implemented
--
--
b23
Standard flue shutdown maximum tem-
perature
60-110°C
105
b24
PVC flue shutdown maximum tempera-
ture
60-110°C
93
b25
CPVC flue shutdown maximum tempera-
ture
60-110°C
98
b26
Not implemented
--
--
b27
Calibration procedure [AUTO SETUP]
5
= Calibration procedure [AUTO SETUP] enabled
All other values
= Calibration procedure [AUTO SETUP] disabled
(See Calibration procedure [AUTO SETUP] on page 329)
0
b28
Not implemented
--
--
Summary of Contents for 0T4D1AWA
Page 1: ...INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...
Page 39: ...334 EN cod 3541V481 Rev 00 06 2021 fig 40 ...
Page 45: ...340 EN cod 3541V481 Rev 00 06 2021 fig 48 fig 49 fig 50 ...
Page 53: ...348 EN cod 3541V481 Rev 00 06 2021 4 4 Technical data table ...
Page 54: ...349 EN cod 3541V481 Rev 00 06 2021 ...
Page 55: ...350 EN cod 3541V481 Rev 00 06 2021 ...
Page 56: ...351 EN cod 3541V481 Rev 00 06 2021 ...
Page 59: ......
Page 60: ......
Page 61: ......