Curve:
select this item and use the buttons
and
DHW
to adjust the de-
sired curve from 1 to 10.
By adjusting the curve to 0, the slid-
ing temperature adjustment is disa-
bled (see fig. 24).
Offset:
Access this sub-menu to access par-
allel offset of the curves using the
buttons
and
DHW
. Refer to
fig. 25 for the characteristics.
OFF:
This item gives access to the "exter-
nal temperature shutdown value.
Use the buttons
and
DHW
to
modify the value (from 0 to 40°C), if
set to 0 the function is disabled. Igni-
tion occurs when the temperature of
the external probe is more than 2°C
lower than the set temperature.
fig. 23
To exit the
Climatic curves setting [OTC]
menu, press the button
repeatedly until reaching
the main screen.
If the room temperature is lower than the desired value, it is advisable to set a higher order curve
and vice versa. Proceed by increasing or decreasing in steps of one and check the result in the
room.
fig. 24- Compensation curves
fig. 25- Example of compensation parallel
curve offset
Summary of Contents for 0T4D1AWA
Page 1: ...INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...
Page 39: ...334 EN cod 3541V481 Rev 00 06 2021 fig 40 ...
Page 45: ...340 EN cod 3541V481 Rev 00 06 2021 fig 48 fig 49 fig 50 ...
Page 53: ...348 EN cod 3541V481 Rev 00 06 2021 4 4 Technical data table ...
Page 54: ...349 EN cod 3541V481 Rev 00 06 2021 ...
Page 55: ...350 EN cod 3541V481 Rev 00 06 2021 ...
Page 56: ...351 EN cod 3541V481 Rev 00 06 2021 ...
Page 59: ......
Page 60: ......
Page 61: ......