Recommended chemical conditioners:
SENTINEL X100 and SENTINEL X200
FERNOX F1 and FERNOX F3
The unit is equipped with a frost protection system that activates the boiler in heating mode
when the system flow water temperature falls below 6°C. The device is not active if the
power and/or gas supply to the unit is turned off. If necessary, to protect the system use a
suitable antifreeze liquid that meets the above requirements and provided for by UNI 8065.
In the presence of adequate chemical/physical system and feed water treatments and re-
lated high cyclicity controls able to ensure the required parameters, for industrial process
applications the product can be installed in open-vessel systems with vessel hydrostatic
height able to ensure compliance with the minimum operating pressure indicated in the
product technical specifications.
The presence of deposits on the boiler exchange surfaces due to non-compliance
with the above requirements will involve non-recognition of the warranty.
2.4 Gas connection
B
Before making the connection, ensure that the unit is
arranged for operation with the type of fuel available.
The gas connection must be made to the relevant con-
nection
(see and fig. 59)
in compliance with current
legislation, using a rigid metal pipe or a continuous
wall flexible hose in stainless steel, placing a gas
valve between the system and boiler. Make sure all the
gas connections are tight. Otherwise there may be a
risk of fire, explosion or suffocation.
2.5 Electrical connections
ATTENTION
B
BEFORE CARRYING OUT ANY OPERATION REQUIR-
ING REMOVAL OF THE CASING, DISCONNECT THE
BOILER FROM THE ELECTRIC MAINS WITH THE
MAIN SWITCH.
NEVER TOUCH THE ELECTRICAL COMPONENTS OR
CONTACTS WITH THE MAIN SWITCH TURNED ON!
DANGER OF ELECTRIC SHOCK WITH RISK OF INJU-
RY OR DEATH!
B
The unit must be connected to an efficient grounding sys-
tem in accordance with applicable safety regulations.
Summary of Contents for 0T4D1AWA
Page 1: ...INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...
Page 39: ...334 EN cod 3541V481 Rev 00 06 2021 fig 40 ...
Page 45: ...340 EN cod 3541V481 Rev 00 06 2021 fig 48 fig 49 fig 50 ...
Page 53: ...348 EN cod 3541V481 Rev 00 06 2021 4 4 Technical data table ...
Page 54: ...349 EN cod 3541V481 Rev 00 06 2021 ...
Page 55: ...350 EN cod 3541V481 Rev 00 06 2021 ...
Page 56: ...351 EN cod 3541V481 Rev 00 06 2021 ...
Page 59: ......
Page 60: ......
Page 61: ......