BlueHelix ALPHA C
280
EN
cod. 3541U152 - Rev. 01 - 04/2021
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature required in the rooms. If the room thermostat is
not installed, the boiler will keep the system at the set system delivery setpoint temperature.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the required temperature in the rooms. The boiler will adjust
the system water according to the required room temperature. For operation with remote timer
control, please refer to the relevant instruction manual.
ECO/COMFORT selection
The unit has a function that ensures a high domestic hot water delivery speed and maximum
comfort for the user. When the device is activated (
COMFORT
mode), the water contained in the
boiler is kept hot, therefore ensuring immediate availability of hot water on opening the faucet,
without waiting times.
The device can be deactivated by the user (
ECO
mode) by pressing the
winter/summer/off
but-
ton (detail 7 - fig. 1) for 5 seconds. In
ECO
mode the display activates the
ECO
symbol (detail 12
- fig. 1). To activate the
COMFORT
mode, press the
winter/summer/off
button again (detail 7 -
fig. 1) for 5 seconds.
Sliding Temperature
When the external probe (optional) is installed, the boiler adjustment system works with "Sliding
Temperature". In this mode, the heating system temperature is regulated according to weather
conditions, to ensure high comfort and energy efficiency throughout the year. In particular, as the
outside temperature increases the system delivery temperature decreases according to a specific
"compensation curve".
With the Sliding Temperature adjustment, the temperature set with the heating buttons (details 3
and 4 - fig. 1) becomes the maximum system delivery temperature. It is advisable to set a maxi-
mum value to allow system adjustment throughout its useful operating range.
The boiler must be adjusted at the time of installation by qualified personnel. However, the user
can make any further adjustments necessary to optimize comfort levels.
Compensation curve and curve offset
Press the reset
button
(detail 6 - fig. 1) for 5 seconds to access the “Sliding temperature” menu;
the display shows “CU” flashing.
Use the DHW buttons (detail 1 - fig. 1) to adjust the desired curve from 1 to 10 according to the
characteristic (fig. 14). By setting the curve to 0, the sliding temperature adjustment is disabled.
Press the heating buttons (detail 3 - fig. 1) to access parallel curve offset; the display shows “OF”
flashing. Use the DHW buttons (detail 1 - fig. 1) to adjust parallel curve offset according to the cha-
racteristic (fig. 15).
Press the heating buttons (detail 3 - fig. 1) to access the menu “shutdown for external temperatu-
re”; the display shows
"SH"
flashing. Use the DHW buttons (detail 1 - fig. 1) to adjust the shutdown
external temperature. If set to 0 the function is disabled; the range varies from 1 to 40°C. Lighting
occurs when the external probe temperature is 2°C lower than the set temperature.
Press the reset
button
(detail 6 - fig. 1) again for 5 seconds to exit the "Sliding Temperature" me-
nu.