4
EN
e)
When operating a power tool outdoors, use
an extension cord suitable for outdoor use.
Use of a cord suitable for outdoor use reduces
the risk of electric shock.
f)
If operating a power tool in a damp
location is unavoidable, use a residual
current device (RCD) protected supply.
Use
of an RCD reduces the risk of electric shock.
3) Personal safety
a)
Stay alert, watch what you are doing and
use common sense when operating a
power tool. Do not use a power tool while
you are tired or under the influence of
drugs, alcohol or medication.
A moment of
inattention while operating power tools may
result in serious personal injury.
b)
Use personal protective equipment. Always
wear eye protection.
Protective equipment
such as dust mask, non-skid safety shoes,
hard hat, or hearing protection used for
appropriate conditions will reduce personal
injuries.
c)
Prevent unintentional starting. Ensure
the switch is in the off-position before
connecting to power source and/or battery
pack, picking up or carrying the tool.
Carrying power tools with your finger on the
switch or energising power tools that have the
switch on invites accidents.
d)
Remove any adjusting key or wrench
before turning the power tool on.
A wrench
or a key left attached to a rotating part of the
power tool may result in personal injury.
e)
Do not overreach. Keep proper footing
and balance at all times.
This enables better
control of the power tool in unexpected
situations.
f)
Dress properly. Do not wear loose clothing
or jewellery. Keep your hair, clothing and
gloves away from moving parts.
Loose
clothes, jewellery or long hair can be caught in
moving parts.
g)
If devices are provided for the connection
of dust extraction and collection facilities,
ensure these are connected and properly
used.
Use of dust collection can reduce dust
related hazards
.
h)
Do not let familiarity gained from frequent
use of tools allow you to become
complacent and ignore tool safety
principles.
A careless action can cause
severe injury within a fraction of a second.
4) Power tool use and care
a)
Do not force the power tool. Use the
correct power tool for your application.
The
correct power tool will do the job better and
safer at the rate for which it was designed.
b)
Do not use the power tool if the switch
does not turn it on and off.
Any power tool
that cannot be controlled with the switch is
dangerous and must be repaired.
c)
Disconnect the plug from the power source
and/or the battery pack from the power
tool before making any adjustments,
changing accessories, or storing power
tools.
Such preventive safety measures
reduce the risk of starting the power tool
accidentally.
d)
Store idle power tools out of the reach
of children and do not allow persons
unfamiliar with the power tool or these
instructions to operate the power tool.
Power tools are dangerous in the hands of
untrained users.
e)
Maintain power tools. Check for
misalignment or binding of moving parts,
breakage of parts and any other condition
that may affect the power tool’s operation.
If damaged, have the power tool repaired
before use.
Many accidents are caused by
poorly maintained power tools.
f)
Keep cutting tools sharp and clean.
Properly maintained cutting tools with sharp
cutting edges are less likely to bind and are
easier to control.
g)
Use the power tool, accessories and
tool bits etc. in accordance with these
instructions, taking into account the
working conditions and the work to
be performed.
Use of the power tool for
operations different from those intended could
result in a hazardous situation.
h)
Keep handles and grasping surfaces dry,
clean and free from oil and grease.
Slippery
handles and grasping surfaces do not allow
for safe handling and control of the tool in
unexpected situations.
Summary of Contents for ESM1015
Page 2: ...2 Fig A Fig B Fig C 1 3 4 5 2 7 3 6 4 5...
Page 108: ...108 RU II 1 a b c 2 a b c d e...
Page 109: ...109 RU f 3 a b c d e f g h 4 a b c...
Page 110: ...110 RU d e f g h 6 O...
Page 112: ...112 RU 3 C C1 5 4 5 4 C2 5 4 D 4 4 4 1 1 6 5...
Page 113: ...113 UK 2012 19 U 300W Ferm Ferm 1...
Page 114: ...114 UK 1 b c 2 a b c d e f 3 a...
Page 115: ...115 UK b c off d e f g h 4 a b c d e f...
Page 116: ...116 UK g h 6 a 1 5 2...
Page 118: ...118 UK D 4 4 4 1 1 6 5 I 2012 19 EU...
Page 119: ...119 EL 300W Ferm Ferm 1 II E fI fi fi fi fi 1 a fi fi b fi fi fi fi c fi fi 2 a fi...
Page 121: ...121 EL fi b fi fi fi fi fi c fi fi d fi fi fi e fi fi f fi g fi fi fi h 6 a b...
Page 123: ...123 EL 3 B 3 C C1 5 4 5 4 5 4 D 4 4 4 On Off A On Off 1 On Off 1 A 6 5...
Page 124: ...124 BG 2012 19 300W Ferm Ferm...
Page 125: ...125 BG II 1 a b c 2 a b c d e f RCD RCD 3 a...
Page 126: ...126 BG b c d e f g h 4 a b c d e f...
Page 128: ...128 BG EN 62841 1 EN 62841 2 4 2 A 2 1 2 3 4 5 6 7 3 B 3 C C1 5 4 5 4 C2 5 4...
Page 129: ...129 BG D 4 4 4 On Off A On Off 1 1 6 5 2012 19 EU...
Page 130: ...130 AR 300 Ferm Ferm 1 1 a b c 2 a b c d e f DCR...
Page 131: ...131 AR 3 a b c d e f g h 4 a b c d e f g h 6 a...
Page 133: ...133 AR 4 1 1 6 5 2012 19 EC...
Page 139: ...139 MK 300W FERM FERM 1 1 a b c 2 a...
Page 140: ...140 MK b c d e f RCD RCD 3 a b c d e f g h a 4 a b c...
Page 141: ...141 MK d e f g h 6 a 1 5 mm2...
Page 143: ...143 MK D 4 4 4 ON OFF A 1 1 A 6 2012 19 EU...
Page 145: ...145 Exploded view...
Page 146: ...146...
Page 148: ...WWW FERM COM 2021 FERM 2112 14...