GB
7
Ferm
Installing the depth stop rod
Fig. 1 + 2
The depth stop rod (13) is used as a gauge to
control the depth of the drilled hole. It can be used
with the combi drill in either the normal drilling
mode or the impact drill mode.
Turn the auxiliary handle (11) counter
•
clockwise about three turns to open the depth
stop rod mounting clamp (14).
Insert the depth rod into the matching hole in
•
the depth stop rod mounting clamp.
Position the depth stop rod so it will contact
•
the work piece when the drill reaches the
appropriate depth.
When the depth stop rod is properly
•
positioned, tighten the depth stop rod
mounting clamp by turning the auxiliary handle
clockwise.
Tighten the handle by hand only. Do not
over tighten the handle or you will
damage the handle or the housing.
Installing drill bits
Fig. 4
Never hold the chuck and use the drill
power to loosen or tighten bits. This can
result in serious injury.
To open the keyless drill chuck, rotate the
•
chuck body (1) in a clockwise direction until
the jaws (16) open wide enough to accept the
bit. (17)
Insert the bit, over the full length of the jaws,
•
into the chuck.
Tighten the chuck jaws onto the bit by turning
•
the chuck body in a counter clockwise
direction.
As the chuck jaws begin to tighten on the bit,
•
you will hear a clicking sound. Continue to
rotate the chuck body until the clicking stops
and you can no longer turn it any further by
hand. The chuck is now locked.
The bit must be properly inserted with all
three of the chuck jaws holding the bit
centred in the chuck. Make sure the
chuck jaws grasp the flat sides of a
screwdriver bit. Failure to do so could
cause the bit to be thrown from the
chuck, resulting in possible serious
injury or damage to the chuck.
To remove a bit, open the keyless drill chuck by
•
rotating the chuck body in a clockwise direc tion
until the chuck jaws open and remove the bit.
Connecting and removing the battery
Fig. 1 + 5
Ensure that the direction reversing switch (8)
•
is in the central position in order to prevent the
appliance from being switched on
unexpectedly.
Insert the battery into the base of the
•
appliance, as shown on the illustration. Push
the battery until it latches in.
Press the locking button (10) on either side
•
before removing the battery, and disengage
the battery from the base of the appliance.
Only use batteries of the following type. Using any
other batteries could cause serious injury or
damage the tool.
CDA1051: FPB-1800L, 18V Lithium-Ion
CDA1053: FPB-1800N, 18V NiMH
The following charger can be used to charge these
batteries.
CDA1052: FPL-1800 (Lithium-Ion and NiMH)
CDA1054: FPL-1800N (NiMH only)
4. OPERATION
Always follow the safety notes and the
relevant safety code.
Hold the appliance firmly and press the drill
steadily onto the workpiece. Do not overload the
appliance. Only use drills with no visible wear.
Worn drills will have a bad effect on the functio-
ning of the appliance.
Do not cover the air vents.
This will reduce the motor cooling, and possibly
lead to overheating the motor.
Adjusting the torque
Fig. 6 + 7
Rotate the adjustment ring (2) to align the correct
torque setting number with the torque indicator
arrow (18). Use the chart below for the correct
torque setting:
1-5: For driving small screws
6-10: For driving medium sized screws into soft
materials
Summary of Contents for CDM1064
Page 2: ...2 Ferm Fig 3 Fig 2 Fig 1...
Page 3: ...3 Ferm Fig 6 Fig 5 Fig 4...
Page 4: ...4 Ferm Fig 9 Fig 8 Fig 7...
Page 58: ...58 Ferm...
Page 59: ...59 Ferm...
Page 60: ...60 Ferm...
Page 63: ...63 Ferm Exploded view...