7
EN
Electrical safety
Always check that the voltage of the
power supply corresponds to the voltage
on the rating plate.
• Do not use the machine if the mains cable or
the mains plug is damaged.
• Only use extension cables that are suitable
for the power rating of the machine with a
minimum thickness of 1.5 mm2. If you use a
extension cable reel, always fully unroll the
cable.
Technical data
Mains voltage
220-240 V~
Mains frequency
50 Hz
Power input
500 W
No-load speed
12,000/min
Grinding disc Diameter
125 mm
Bore
22.2 mm
Spindle thread
M14
Weight
1.69 kg
Noise and vibration
Sound pressure (Lpa) (K=3dB)
86 dB(A)
Acoustic power (Lwa) (K=3dB)
97 dB(A)
Vibration (K=1.5 m/s
2
)
2.48 m/s
2
Vibration level
The vibration emission level stated in this
instruction manual has been measured in
accordance with a standardised test given in
EN 60745; it may be used to compare one tool
with another and as a preliminary assessment of
exposure to vibration when using the tool for the
applications mentioned
- using the tool for different applications, or with
different or poorly maintainted accessories,
may significantly increase the exposure level
- the times when the tool is switched off or when
it is running but not actually doing the job, may
significantly reduce the exposure level
Protect yourself against the effects of vibration by
maintaining the tool and its accessories, keeping
your hands warm, and organizing your work
patterns
Wear hearing protection.
DESCRIPTION (FIG. A)
Your angle grinder has been designed for grinding
and cutting masonry and steel.
1. On/off switch
2. Spindle lock button
3. Spindle
4. Guard
5. Main grip
6. Auxiliary grip
ASSEMBLY
Before assembly, always switch off the
machine and remove the mains plug from
the mains.
Mounting and removing the guard & grinding
disc (fig. B)
Do not use the machine without the guard.
Mounting
• Place the machine on a table with the spindle
(3) facing upwards.
• Keep the spindle lock button (2) pressed and
remove the flange (7) using the flange key (8).
• If necessary, remove the grinding disc (9).
• Remove the flange (10).
• Mount the guard (4). Secure the guard (4) by
tightening the screw (11) and the nut (12).
• Mount the flange (10).
• If necessary, mount the grinding disc (9).
• Keep the spindle lock button (2) pressed and
mount the flange (7) using the flange key (8).
Removing
• Place the machine on a table with the spindle
(3) facing upwards.
• Keep the spindle lock button (2) pressed and
remove the flange (7) using the flange key (8).
• If necessary, remove the grinding disc (9).
• Remove the flange (10).
• Remove the guard (4) by loosening the screw
(11) and the nut (12).
• Mount the flange (10).
• If necessary, mount the grinding disc (9).
• Keep the spindle lock button (2) pressed and
mount the flange (7) using the flange key (8).
Summary of Contents for AGM1102
Page 2: ...2 Fig A 6 1 5 4 2 3...
Page 3: ...4 3 10 9 7 8 11 12 4 2 3 Fig B...
Page 4: ...4 Fig C 6 13 13...
Page 67: ...67 EL AGM1102 Ferm Ferm...
Page 68: ...68 EL 80...
Page 71: ...71 EL 2012 19 EU...
Page 72: ...72 MK AGM1102 FERM FERM...
Page 73: ...73 MK ja 80 on off...
Page 75: ...75 MK B ja 3 2 7 8 9 10 4 4 11 12 10 9 2 7 8 3 2 7 8 9 10 4 11 12 10 9 2 7 8 C 6 13 6 13 A...
Page 76: ...76 MK 2012 19 EU...