Admin menu

User name

SYSOP name. Default is Administrator

Administrator password

SYSOP password (only sysop with sysop password can change password next
time)

Reboot bridge

Device should be rebooted after all changes. This has the same effect as unp-
lugging the device from power and plugging it in again.

Reset to factory defaults

After  wrong  changes  or  problems  with  many  parameters  you  can  reset  to
default factory settings.

Package content

1x Outdoor Client
1x Power Over Ethernet HUB
1x User guide

Atttention!

This  device  is  only  for  expert  use.  If  you  are  not  sure  about  one  of  the

points in this guide ask Ferimex IT for help or consult a network expert.

10

OUTDOOR CLIENT

Summary of Contents for Outdoor Client

Page 1: ...Ferimex IT spol s r o V tvarn 8 Bratislava officeba ferimexit sk tel 421 2 4564 1701 www ferimex com Outdoor Client User s Guide...

Page 2: ...d operate in the free 2 4 Ghz band The device supports Infrastructure or Ad Hoc 802 11b modes The device can operate at distances over 10km while maintaining a transmission rate of 11 Mbps In ideal co...

Page 3: ...Two screws with the holder is all you need for the installation Tighten the screws in the front panel only then is the Outdoor Client weatherproof With an ISM antenna holder Two screws in the horizont...

Page 4: ...rowser go to the address http 192 168 5 99 Your computer s ethernet card must be on the same network for example 192 168 5 90 as the Outdoor Client and the Outdoor Client must be connected to the netw...

Page 5: ...ode A special mode primarily for point to point connection use It is possible to connect the device to only one other device running in the same Ad Hoc mode Required parameters are the ESSID string an...

Page 6: ...ork channel You can choose the channel in AD Hoc mode In infrastructure mode you don t need to set the channel The Outdoor client will scan the band and stop after it finds traffic with the same ESSID...

Page 7: ...ication process without using WEP Shared Key Only devices with correct WEP phrase during the authentification process can connect to the Outdoor Client Both Outdoor Client can be connected with any de...

Page 8: ...w Upgrade uploads It is possible to change firmware when this parameter is on Cloning Bridge Wireless interface has the same MAC address as the first device connected to the network The Bridge table T...

Page 9: ...ect as unp lugging the device from power and plugging it in again Reset to factory defaults After wrong changes or problems with many parameters you can reset to default factory settings Package conte...

Page 10: ...5 and 11Mbps CCK Media Access Protocol CSMA CA with ACK Communication Half duplex Transmit power 14 dBm 1 at nominal temp range Receive sensitivity 11 Mbps 10 5 BER at 81 dBm Transmission rates Mbps 1...

Page 11: ...Ferimex IT spol s r o V tvarn 8 Bratislava officeba ferimexit sk www ferimex com...

Reviews: