1. DESCRIPTION
1.01 Introduction
The
Falcon II
is defined as a “room sealed” combination boiler, all air required for combustion is taken from outside the
room in which it is installed. It is a new high performance gas fired heat generator for central heating and domestic hot
water production. A special feature of this boiler is its built-in electronic flame ignition and control unit making burner
operation completely automatic and safe. The main components are as follows:
• Copper heat exchanger consisting of three finned tubes specifically shaped for high efficiency.
• There are three copper coils inserted in the three heating circuit tubes. These represent the domestic hot water heat
exchanger. Their shape and high exchange surface area enable the full output of the boiler to be absorbed.
• Ceramic fibre insulated combustion chamber
• 16 stainless steel bladed burners specifically designed for this boiler.
• Fan for discharge of combustion products and intake of combustion air.
• Differential air pressure switch. For safety reasons, this ensures the burner ignites only when the fan is
functioning correctly.
• Hermetically sealed compartment made from corrosion-resistant steel enclosing the above components.
• Combination gas safety valve with modulator, complete with pressure stabiliser.
• Flowmeter giving the domestic hot water circuit precedence over the central heating circuit.
• Pressure relief valve for the central heating circuit set to open at 3 bar.
• Built-in Expansion vessel.
• Variable speed pump.
• Central heating flow temperature adjustment thermostat.
• Domestic hot water flow temperature adjustment thermostat.
• Central heating limit thermostat.
• Overheat safety thermostat.
• Electronic control unit for automatic flame ignition and control.
• Central heating low water pressure cut off switch.
• Domestic hot water flow temperature sensor.
• Central heating flow temperature sensor.
1.02 Instructions and regulations
Assembly, installation, first start up and maintenance must be carried out by competent persons only, in accordance
with all current technical regulations and directives.
C.O.S.H.H.
Materials used in the manufacture of this appliance are non hazardous and no special precautions are required
when servicing.
Related Documents
This appliance must be installed strictly in accordance with these instructions.
The Gas Safety Regulations (Installations & Use) 1996.
The Local Building Regulations.
The Building Regulations.
The Buildings Standards (Scotland - Consolidated) Regulations.
British Standards Codes of Practice:
B.S.
7593 1992 TREATMENT OF WATER IN DOMESTIC HOT WATER CENTRAL HEATING SYSTEMS
B.S.
5546 1990 INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES
B.S.
5440 PART 1 FLUES
B.S.
5440 PART 2 AIR SUPPLY
B.S.
5449 1990 FORCED CIRCULATION HOT WATER SYSTEMS
B.S.
6798 1987 INSTALLATION OF GAS FIRED HOT WATER BOILERS
B.S.
6891 1989 GAS INSTALLATIONS
B.S.
7671 1992 IEE WIRING REGULATIONS
B.S.
4814 1990 SPECIFICATION FOR EXPANSION VESSELS
B.S.
5482 1994 INSTALLATION OF LPG
Model Water Bye Laws
For Northern Ireland the rules in force apply