background image

Fenwal Controls 
400 Main Street 
Ashland, MA  01721 
Tel. (508) 881-2000  

© 

Kidde-Fenwal Inc.   06-237657-001 

 Rev A

C

 

EU DECLARATION OF CONFORMITY 

We 

Company Name: 

 

Kidde-Fenwal Inc. 

Postal Address: 

400 Main Street 

City and Post Code:  

Ashland, MA 01721 

Tel:   

508-881-2000 

Declare that the DoC is issued under sole responsibility and belongs to the following product: 

Apparatus Model(s) 

Series 35-40, 35-53, 35-60, 35-61, 35-63, 35-608, 35-65, 35-66, 35-9X 

Type: 

Fitting 

Batch Number  

Date code and Revision Level Assigned per production lot, (YYWW RR) 

Object of the Declaration: 

Series 35-40, 12/24Vdc Direct Spark Automatic Gas Ignition Controllers 
Series 35-53, 12Vdc Direct Spark Automatic Gas Ignition Controllers 
Series 35-60, 35-61, 35-63, 35-608 24Vac Direct Spark Automatic Gas Ignition 
Series 35-65 & 35-66 24Vac Hot Surface Automatic Gas Ignition Controllers 
Series 35-9X Platform Ignition Module

SERIES 35-40 

SERIES 35-53 

SERIES 35-60/61/63/608 

SERIES 35-65/66 

SERIES 35-9X 

The object of the declaration described above is in conformity within the relevant union 
harmonization legislation: 

Gas Appliance Regulation

(

EU) 2016/426 

Low Voltage Directive: 

2014/35/EC 

EMC Directive:

2014/30/EC

Rohs 

2011/65/EU

The following harmonized standards and technical specifications have been applied: 

EN298:2012:    

Automatic Burner Control systems for Burners and appliances burning gaseous or liquid fuels. 

EN13611:2007_A2:2011: 

Safety and control devices for Gas Burners and Gas burning appliances – General Requirements. 

Name of Notified Body & Number: 

BSI Group, 0086, EU Type Examination Certification 

Notified Body Certificate No.: 

Series 35-40:   

CE682407 

Series 35-53   

CE682404 

Series 35-60/61/63/608 

CE682405 

Series 35-65/66 

CE682406 

Series 35-9x   

CE

690652

 

Surveillance Audit Notified Body: 

BSI Group 

For copies of the Installation Instructions and the EU DoC, got to 

www.fenwalcontrols.com

, - Document Library - Data sheets. 

Paul Finn 

Kidde-Fenwal, Inc. Ashland, MA USA 

01

 

Oct

 2018 

Paul Finn, Certification Engineer 

Place of Issue:  

Date of Issue 

Name 

Summary of Contents for 35-53CE Series

Page 1: ...s the blower function if not required allowing one part to address all service or OEM needs Agency Certifications EN298 CE 584099 Classification BMRVXN Mobile Applications DC supply type A B C Code Compliant to AS 4625 2008 AS 4622 2004 CAN CSA E60730 1 ANSI Z21 20 CAN CSA C22 2 No 60730 2 5 Compliant with current RoHS standards SPECIFICATIONS Input Power Control 9 2 to 15 VDC from a stor age batt...

Page 2: ...stic LED will indicate the fault code for igni tion lockout 3 Flashes Flame Failure FLAME FAILURE RECYCLE MODE Standard With the Recycle after Loss of Flame option upon loss of flame the gas valve is de energized and the control proceeds to inter purge before attempting to relight the flame Multi try models permit three tries for ignition including inter purges If the burner relights normal operat...

Page 3: ...t has been exposed to water must be replaced WARNING All wiring must be done in accordance with both local and national electrical code and by a trained service technician Wiring must be at least 18 AWG rated for 105 C or higher WARNING The 35 53CE uses voltages of shock hazard potential Wiring and initial operation must be done by qualified service technician WARNING Operation outside specificati...

Page 4: ...wer Relay Figure 2 Local Sense without Blower Relay Figure 3 Remote Sense with Blower Relay Figure 4 Remote Sense without Blower Relay DIMENSIONS INTEGRAL STANDOFF 4 250 3 750 250 3 250 2 750 250 6 PIN EDGE CONNECTOR 1 25 NOM 218 MAX 250 Q C H V TERMINAL 164 010 DIA 4 MOUNTING HOLES ...

Page 5: ...lectrode Location Proper location of electrode assembly is important for optimum system performance The electrode assembly should be located so that the tips are inside the flame envelope and about 1 2 inch 1 2 cm above the base of the flame as shown Notes Ceramic insulators must not be in or close to the flame Electrode assemblies must not be adjusted or disassembled Electrodes are NOT field adju...

Page 6: ...s void Troubleshooting Guide Symptom Recommended Actions 1 Dead A Miswired B Transformer battery fault C Fuse circuit breaker fault D No voltage at PWR or AIR E Bad control 2 Thermostat on no blower output A Miswired or failed air flow switch B Faulty thermostat no voltage at thermostat terminal TH C Faulty control 3 Airflow Switch input okay but no TFI after purge delay A Miswired B Faulty contro...

Page 7: ... X X X X DESCRIPTION Trial for Ignition Time 1 5 econds 3 7 econds 5 10 econds 7 25 econds S S S S Inter Purge 0 None 1 15 econds 3 25 econds S S Product Designation 2 CE EN298 Standard Recycle 3 CE EN298 Special Configuration A 3 in this location indicates a special configuration Consult Fenwal controls for operating characteristics of this control Pre Purge 0 None 1 15 Seconds 3 25 Seconds Tries...

Page 8: ...3 SERIES 35 60 61 63 608 SERIES 35 65 66 SERIES 35 9X The object of the declaration described above is in conformity within the relevant union harmonization legislation Gas Appliance Regulation EU 2016 426 Low Voltage Directive 2014 35 EC EMC Directive 2014 30 EC Rohs 2011 65 EU The following harmonized standards and technical specifications have been applied EN298 2012 Automatic Burner Control sy...