Fema Electronica S Series User Manual Download Page 5

User’s Manual S40-R

User’s Manual S40-R

FEMA ELECTRÓNICA - Page 5

Range and scaling 

Pot.<5K

Scaling 0/99.99%=0/99.99%
Alarms 1,2 and 3
   Active 

Off (not managed)

   Type 

maximum

   Setpoint 

1000

   Hysteresis 

0 counts

   Delay 

0.0 seconds

   Setpoint2  

Off

Display
   Fixed digits 

Off

   Average 

Off

   Steps 

Off

   Left zeros 

Off

   Add zero to the right 

Off

   Memory of maximum  -1999
   Memory of minimum 

9999

   Peak & Hold 

Off

Tools
   Segments 

Off

   Password 

Off

   Brightness 

3

1.9 Default factory configuration

The instrument has two menus accessible to the user :

 “

Configuration Menu”

 (key SQ)

 “

Information Menu”

 (key UP)

The 

“Configuration Menu”

 allows to change the configuration 

of the instrument. Access to the 

“Configuration Menu”

 can be 

password protected with the function “

PASSWORD

”. During 

operation with the 

“Configuration Menu”

 the alarms are kept 

on-hold

”. When leaving the 

“Configuration Menu”

 the instru-

ment performs a restart, and new configuration is applied. On 

restart of the instrument, also the control output modules are 
restarted (relays, analogue outputs, ...).

The 

“Information Menu”

 is for information only, and it does not 

accept changes on the displayed information. To enter the 

“In-

formation Menu”

 press the “

UP

” button. It is not affected by 

the “PASSWORD” function. Leaving the 

“Information Menu”

 

returns to the measuring state of the instrument, without 
restart of the unit.

Rollback - 

After 30 seconds without interaction from the 

operator, the instrument leaves the menu and returns to the 

previous working mode. In case of configuration menu, all 

changes are discarded.

Button SQ -

 Selects the menu entry currently displayed. 

When entering a numeric value (for example a setpoint value) 
validates the value on display.

Button UP -

 Moves vertically on the menu entries. When 

entering a numeric value (for example a setpoint value) 

modifies the current digit by increasing its value up from 0 to 

1, 2, 3, 4, 5, 6, 7, 8, 9.

Button LE -

 Leaves the current menu. Pressing LE several 

times will leave all menus. When leaving all menus in the 

configuration menu, changes will be saved . When entering 

a numeric value  (for example a setpoint value) it moves from 

one digit to the next. Each digit value can then be modified  

with the UP button.

1.8 Operating the menus

Summary of Contents for S Series

Page 1: ...earization maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Universal AC and DC po...

Page 2: ...dard IP54 front protection with optional upgrade to IP65 protection Connections via plug in screw terminals and configuration via three front push buttons For application on industrial environments S4...

Page 3: ...wer line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag 6 7 8 9 0 1 2...

Page 4: ...ec 0 to 99 signal Power Power H 85 to 265 Vac dc Power L 11 to 60 Vdc and 24 48Vac Consumption 4W Isolation 3500Veff for power H 2000Veff for power L all levels tested for 60 seconds Configuration 3 f...

Page 5: ...ue outputs The Information Menu is for information only and it does not accept changes on the displayed information To enter the In formation Menu press the UP button It is not affected by the PASSWOR...

Page 6: ...ut High Display High Decimal Point Alarm1 Setpoint Hysteresis Delay Setpoint2 Counts Seconds Second setpoint Auto correction Auto High Auto Low Alarms Signal Low Display Low Signal High Display High R...

Page 7: ...zation Password Version Points Enter signal values Input and associated display val ues Display for each linearization point Then activate Act to On In case of error verify the points data Select pass...

Page 8: ...alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is 1000 and 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays Function...

Page 9: ...al while hold is active 1 10 7 Tools 1 10 8 Menu OptX Options When the instrument detects that the displayed value does not correspond to the expected value the display will flash and alternate with a...

Page 10: ...he configured input signal range 4 20mA 0 10Vdc and the values for input low ILo display low dLo input high IhI and display high dhI Maximum MAX Value of the maximum display Minimum MIn Value of the m...

Page 11: ...to the 61010 1 CE security regulation and is designed for applications on industrial environ ments See the CE Declaration of Conformity further in this document for information on the category of meas...

Page 12: ...AO modules can be installed in one S Series panel meter For more information see document 2657_S40_OPTIONAL_ MODULES at www fema es Module with 1 relay Up to a maximum of two R1 modules can be instal...

Page 13: ...contacts Common NO NC Maximum current 6A resistive load each relay Voltage 250 Vac continuously Installable at slot Opt 1 R2 fills OPT1 R4 fills OPT1 and OPT2 Terminal Plug in screw terminals pitch 3...

Page 14: ...User s Manual S40 R FEMA ELECTR NICA Page 14 T H I S P A G E B L A N K...

Page 15: ...User s Manual S40 R FEMA ELECTR NICA Page 15 T H I S P A G E B L A N K...

Page 16: ...other products ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 72...

Reviews: