User’s Manual S40-R

FEMA ELECTRÓNICA - Page 10

A

B

You may need to access the inside of the instrument to insert 

additional modules. Use a flat screwdriver to unlock the upper 

clips marked with “A”. Then unlock the lower clips marked 

with “B” and move out the front filter. Let the inside of the 

instrument slide out of the housing.

To reinsert the instrument make sure that all modules are 
correctly connected to the pins on the display module. Place 
all the set into the housing, assuring that the modules cor-

rectly fit into the internal guiding slides of the housing. Once 

introduced,  place  again  the  front  filter  by  clipping  first  the 

upper clips “A” and then the lower clips “B”.

Important - If your instrument was delivered with the IP65 front 
seal option, accessing the inside of the instrument will perma-
nently break the IP65 seal on the areas of clips “A” and “B”.

1.13 Accessing the instrument

Configuration (Conf) -

 Informs the configured input signal 

range (4/20mA, 0/10Vdc, ...), and the values for input low 
“ILo”, display low “dLo”, input high “IhI” and display high “dhI”.

Maximum (MAX) - 

Value of the maximum display.

Minimum (MIn) - 

Value of the minimum display

AlarmX (ALX) - 

Configuration of  alarm X. The sequence of 

information shows if the alarm is being managed (“On/Off”), 
the alarm type (“Max/Min”), the setpoint, the hysteresis value, 
the activation delay and the value of setpoint2 (“Off” or the 
setpoint2 value).

OptionX (OptX) - 

Type of module installed. If there is no 

module shows “nonE”.

Measure (MEAS)- 

Multimeter function. Shows the value of 

the input signal without scaling. This is the real value the 
instrument is receiving on terminals, in Vdc or mA.

1.12.1 Information menu

1.12 Information menu

Configuration

See menu for Alarm1

Alarm1

Maximum

Minimum

Memory of minimum

Option1

Option installed

Option2

Option installed

Measure

Range (Rat.,Pot<5K, Pot<5M)

Input Low

Display Low

Input High

Display High

Memory of maximum

“On / Off”

“Max” / “Min”

Setpoint

Hysteresis

Delay

Setpoint2

Counts

Seconds

Second 
setpoint

Range”

Measured value

Press UP button to enter Information Menu

Summary of Contents for S Series

Page 1: ...earization maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Universal AC and DC po...

Page 2: ...dard IP54 front protection with optional upgrade to IP65 protection Connections via plug in screw terminals and configuration via three front push buttons For application on industrial environments S4...

Page 3: ...wer line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag 6 7 8 9 0 1 2...

Page 4: ...ec 0 to 99 signal Power Power H 85 to 265 Vac dc Power L 11 to 60 Vdc and 24 48Vac Consumption 4W Isolation 3500Veff for power H 2000Veff for power L all levels tested for 60 seconds Configuration 3 f...

Page 5: ...ue outputs The Information Menu is for information only and it does not accept changes on the displayed information To enter the In formation Menu press the UP button It is not affected by the PASSWOR...

Page 6: ...ut High Display High Decimal Point Alarm1 Setpoint Hysteresis Delay Setpoint2 Counts Seconds Second setpoint Auto correction Auto High Auto Low Alarms Signal Low Display Low Signal High Display High R...

Page 7: ...zation Password Version Points Enter signal values Input and associated display val ues Display for each linearization point Then activate Act to On In case of error verify the points data Select pass...

Page 8: ...alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is 1000 and 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays Function...

Page 9: ...al while hold is active 1 10 7 Tools 1 10 8 Menu OptX Options When the instrument detects that the displayed value does not correspond to the expected value the display will flash and alternate with a...

Page 10: ...he configured input signal range 4 20mA 0 10Vdc and the values for input low ILo display low dLo input high IhI and display high dhI Maximum MAX Value of the maximum display Minimum MIn Value of the m...

Page 11: ...to the 61010 1 CE security regulation and is designed for applications on industrial environ ments See the CE Declaration of Conformity further in this document for information on the category of meas...

Page 12: ...AO modules can be installed in one S Series panel meter For more information see document 2657_S40_OPTIONAL_ MODULES at www fema es Module with 1 relay Up to a maximum of two R1 modules can be instal...

Page 13: ...contacts Common NO NC Maximum current 6A resistive load each relay Voltage 250 Vac continuously Installable at slot Opt 1 R2 fills OPT1 R4 fills OPT1 and OPT2 Terminal Plug in screw terminals pitch 3...

Page 14: ...User s Manual S40 R FEMA ELECTR NICA Page 14 T H I S P A G E B L A N K...

Page 15: ...User s Manual S40 R FEMA ELECTR NICA Page 15 T H I S P A G E B L A N K...