All instruments are warranted against all manufacturing 
defects for a period of 24 MONTHS from the shipment date. 
This warranty does not apply in case of misuse, accident or 
manipulation by non-authorized personnel. In case of mal-
function get in contact with your local provider to arrange for 
repair. Within the warranty period and after examination by 
the manufacturer, the unit will be repaired or substituted when 
found to be defective. The scope of this warranty is limited to 
the repair cost of the instrument, not being the manufacturer 
eligible for responsibility on additional damages or costs. .

1.14 Warranty

Manufacturer 

FEMA ELECTRÓNICA, S.A.

 

Altimira 14 - Pol. Ind. Santiga

 

E08210 - Barberà del Vallès

 

BARCELONA - SPAIN 

 

www.fema.es - [email protected]

Products -  

S40-R

The manufacturer declares that the instruments indicated comply with the 
directives and rules indicated below.

Directive of electromagnetic compatibility 2004/108/CEE
Directive of low voltage 73/23/CEE

Security rules 61010-1

Equipment “Fixed” 
 

“Permanently connected”

Pollution degree 1 and 2 (without condensation) 
Isolation Double
Category CAT-II

Emission rules

61000-6-4  

Generic rule of emission

Immunity rules

61000-6-2 

Generic rules of immunity

61000-4-2 

By contact ±4KV - Criteria B

 

On air ±8KV - Criteria B

61000-4-3  

Criteria A

61000-4-4  

On AC power lines: ±2KV - Criteria B

 

On DC power lines: ±2KV - Criteria B

 

On signal lines : ±1KV - Criteria B

61000-4-5 

Between AC power lines ±1KV - Criteria B 

 

Between DC power lines ±0.5KV - Criteria B

61000-4-6 

Criteria A

61000-4-8 

30A/m at 50Hz - Criteria A

61000-4-11 

0% 1 cycle Criteria A

 

40% 10 cycle Criteria A

 

70% 25 cycle Criteria B

 

0% 250 cycle Criteria B

Barberà del Vallès October 2009
Daniel Juncà - Quality Manager

1.16 CE declaration of conformity

1.15 Installation precautions

This instrument has been designed and verified according to the 61010-1 

CE security regulation, and is designed for applications on industrial environ-
ments. See the “CE Declaration of Conformity” further in this document for 
information on the category of measure and the degree of pollution levels 
that apply.

Installation  of  this  instrument  must  be  performed  by  qualified  personnel 

only. This manual contains the appropriate information for the installation. 

Using the instrument in ways not specified by the manufacturer may lead 

to a reduction on the specified protection level. Disconnect the instrument 

from power before starting any maintenance and / or installation action.

The instrument does not have a general switch and will start operation as 
soon as power is connected. The instrument does not have protection fuse, 
the fuse must be added during installation.

The instrument is designed to be panel mounted. An appropriate ventilation 
of the instrument must be assured. Do not expose the instrument to excess 
of humidity. Maintain clean by using a humid rag and do NOT use abrasive 
products such as alcohols, solvents, etc.

General recommendations for electrical installations apply, and for proper 
functionality we recommend : if possible, install the instrument far from 

electrical noise or magnetic field generators such as power relays, electri

-

cal motors, speed variators, ... If possible, do not install along the same 
conduits power cables (power, motor controllers, electrovalves, ...) together 
with signal and/or control cables.

Before proceeding to the power connection, verify that the voltage level 
available matches the power levels indicated in the label on the instrument.

In case of fire, disconnect the instrument from the power line, fire alarm 

according  to  local  rules,  disconnect  the  air  conditioning,  attack  fire  with 

carbonic snow, never with water.

Risk of electrical shock. Instrument terminals can be connected 
to dangerous voltage.

Instrument protected with double isolation. No earth connection 
required.

Instrument is in conformity with CE rules and regulations. See 
“CE Declaration of Conformity” further in this document.

Summary of Contents for S Series

Page 1: ...earization maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Universal AC and DC po...

Page 2: ...dard IP54 front protection with optional upgrade to IP65 protection Connections via plug in screw terminals and configuration via three front push buttons For application on industrial environments S4...

Page 3: ...wer line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag 6 7 8 9 0 1 2...

Page 4: ...ec 0 to 99 signal Power Power H 85 to 265 Vac dc Power L 11 to 60 Vdc and 24 48Vac Consumption 4W Isolation 3500Veff for power H 2000Veff for power L all levels tested for 60 seconds Configuration 3 f...

Page 5: ...ue outputs The Information Menu is for information only and it does not accept changes on the displayed information To enter the In formation Menu press the UP button It is not affected by the PASSWOR...

Page 6: ...ut High Display High Decimal Point Alarm1 Setpoint Hysteresis Delay Setpoint2 Counts Seconds Second setpoint Auto correction Auto High Auto Low Alarms Signal Low Display Low Signal High Display High R...

Page 7: ...zation Password Version Points Enter signal values Input and associated display val ues Display for each linearization point Then activate Act to On In case of error verify the points data Select pass...

Page 8: ...alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is 1000 and 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays Function...

Page 9: ...al while hold is active 1 10 7 Tools 1 10 8 Menu OptX Options When the instrument detects that the displayed value does not correspond to the expected value the display will flash and alternate with a...

Page 10: ...he configured input signal range 4 20mA 0 10Vdc and the values for input low ILo display low dLo input high IhI and display high dhI Maximum MAX Value of the maximum display Minimum MIn Value of the m...

Page 11: ...to the 61010 1 CE security regulation and is designed for applications on industrial environ ments See the CE Declaration of Conformity further in this document for information on the category of meas...

Page 12: ...AO modules can be installed in one S Series panel meter For more information see document 2657_S40_OPTIONAL_ MODULES at www fema es Module with 1 relay Up to a maximum of two R1 modules can be instal...

Page 13: ...contacts Common NO NC Maximum current 6A resistive load each relay Voltage 250 Vac continuously Installable at slot Opt 1 R2 fills OPT1 R4 fills OPT1 and OPT2 Terminal Plug in screw terminals pitch 3...

Page 14: ...User s Manual S40 R FEMA ELECTR NICA Page 14 T H I S P A G E B L A N K...

Page 15: ...User s Manual S40 R FEMA ELECTR NICA Page 15 T H I S P A G E B L A N K...

Page 16: ...other products ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 72...

Reviews: