The Perfect Shower Every Time

Refer to installation leafl et for Feltonmix Shower Mixing Valves.

Step 4 should read: Position the wallplate over the valve outlet. Position 
the anti-scald washer in the recess provided  and secure by fi tting the 
two 1 

1

/

 x 7 screws through the slots of the anti-scald washer and into 

the valve body lugs.

In normal cases, the fixing screws will be in the mid-slot position as 
shown above.

Tighten screws alternately until wallplate is firmly clamped to the wall. 

Warning

: Do 

not

 over-tighten.

To provide a warmer shower, loosen the two fixing screws, rotate the 
anti-scald washer slightly clockwise and re-fasten.

To provide a cooler shower, loosen the two fixing screws, rotate the 
anti-scald washer slightly counter-clockwise and re-fasten.

Instruction for fi tting Anti-Scald Washer

Stop

NORMAL POSITION 
OF WASHER

1

/

 x 7

mounting screws