CLUTCH ASSEMBLY
9.5 ...... Actuator Adjustment
The actuator should only be adjusted after the over-travel has been
checked and if necessary adjusted, see sections 9.2 and 9.3.
Slacken the two solenoid fixing screws, using a 4mm allen key, and
move the solenoid body "up" to reduce the actuator clearance and
"down" to increase the actuator clearance.
Tighten the screws and check the actuator clearance. Re-adjust if
the clearance is not correct and ensure that the solenoid screws
are fully tightened after adjustment.
Finally adjust the actuator stop so that it just touches the actuator
when the solenoid is operated.
9.6 ...... Collar Position - Measurement
The machine should print the top of a number at the required
distance from the top of the sheet and this distance corresponds to
the scale on the numbering head collars.
The scale is read off the back edge of the numbering head, and is
affected by the print position adjustment, so the print position
control must be in it's mid-point which is with the end of the knob
75mm / 3" away from the side-frame of the machine.
On the suction machine the print position is greatly affected by the
machine speed so should be set with the speed control at posn. '3'.
Adjustment of the stop collar position is always necessary after
adjusting the over-travel or fitting a new clutch and is achieved
with the machine fully assembled. (See section 9.7 on page 32)