11
en
Mounting the auxiliary handle
(figure 4).
Screw in and firmly tighten the auxiliary han-
dle.
Filling the coolant container
(figure 5).
Prevent the flow of liquid
along the cable into the
socket outlet or into the core drill unit, as
this can lead to electric shock. Tie a bow in
the cable near the plug, so that any liquid can
drip off.
Unscrew the cap from the coolant con-
tainer.
Fill with water soluble cutting fluid like Slug-
ger Cutting Fluid.
Replace the cap back onto the coolant con-
tainer.
Do not use the magnetic core drill unit when
the cooling-lubricant system is defective.
Each time before operating,
check for tight-
ness against leaks and for cracks in the hoses.
Prevent liquids from entering or penetrating
electrical components.
Auxiliary handle
WARNING
Coolant container