26
en
PRCD personal protection switch (*) (see page 8)
The PRCD personal protection switch is specifically for
your protection; therefore, do
not
misuse it as on
On/Off switch.
If the PRCD personal protection switch is damaged, e.g.
due to contact with water, do not use it any more.
The PRCD personal protection switch is indispensable;
it is used for protection of the power tool operator
against electric shock. Under fault-free operation, the
control lamp of the PRCD personal protection switch
lights up.
Check the operability of the PRCD personal protection
switch before beginning to work:
1. Connect the plug of the PRCD personal protection
switch with the mains socket outlet.
2. Press the RESET–button. The indication light on the
PRCD personal protection switch lights up.
3. Disconnect the plug from the socket outlet. The indi-
cation light goes out.
4. Repeat steps 1. and 2.
5. Press the TEST–button; the indication light goes out.
If the indication light does not go out, do not run the
machine. In this case, contact the customer service.
6. Press the RESET–button; when the indication light
lights up, the machine can now be switched on.
Do not use the PRCD personal protection switch for
switching the power tool on and off.
Repair and customer service.
When working metal under extreme oper-
ating conditions, it is possible for conductive
dust to settle in the interior of the power
tool. The total insulation of the power tool can be
impaired. Blow out the interior of the power tool via
the ventilation slots frequently with dry and oil-free
compressed air.
Renew stickers and warning indications on the power
tool when aged and worn.
When the machine’s power supply cable is damaged, it
must be replaced using a specially prepared power sup-
ply cable with PRCD personal protection switch (*),
available from the FEIN customer service.
Products that have come into contact with asbestos
may not be sent in for repair. Dispose of products con-
taminated with asbestos according to the applicable
country-specific regulations for such disposal.
For FEIN power tools and accessories in need of repair,
please contact your FEIN after-sales service. The
address can be found on the Internet under
www.fein.com.
The current spares parts list for this power tool can be
found on our website at www.fein.com.
Use only original spare parts.
If required, you can change the following parts your-
self:
Application tools, coolant container, contact protector
Warranty and liability.
The warranty for the product is valid in accordance
with the legal regulations in the country where it is mar-
keted. In addition, FEIN also provides a guarantee in
accordance with the FEIN manufacturer’s warranty dec-
laration.
The delivery scope of your power tool may include
only a part of the accessories described or shown in this
Instruction Manual.
Error message/
Response of Magnet Button
Meaning
Corrective Action
Indicator lights up green
Magnetic holding power possibly suffi-
cient.
–
Indicator flashes green
Magnetic holding power possibly
insufficient.
Even when working on steel materials
where the material thickness is below
12 mm, the work piece must be made
thicker with an additional steel plate in
order to ensure the magnetic holding
power.
Indicator lights up red for
1 second
– Motion sensor has actuated
– Overload shut-off has actuated
– Incorrect mains voltage
After malfunction correction, the power
tool can be switched on again.
Indicator lights up red con-
tinuously
– Incorrect mains voltage/mains fre-
quency
– Button is blocked when switching
on
After malfunction correction, the power
tool can be switched on again.
If the error occurs frequently, send the
machine to your FEIN customer service
agent.
Indicator flashes red con-
tinuously
Power tool is defective.
Send the machine to your FEIN customer
service agent.
27
en
Declaration of conformity.
This
CE declaration
is only valid for European Union
and EFTA (European Free Trade Association) countries
and only for products intended for the EU- or EFTA
market. After placing the product on the EU market the
UKCA mark loses its mark validity.
The
UKCA declaration
is only valid for the Great
Britain market (England, Wales and Scotland) and only
for products intended for the Great Britain market.
After placing the product on the Great Britain market
the CE mark loses its mark validity.
FEIN declares itself solely responsible for this product
conforming with the relevant provisions given on the
last page of this Instruction Manual.
Technical documents at:
C. & E. Fein GmbH
Hans-Fein-Straße 81
73529 Schwäbisch Gmünd-Bargau, Germany
Environmental protection, disposal.
Packaging, worn out power tools and accessories
should be sorted for environmental-friendly recycling.
Summary of Contents for KBC 36 MAGFORCE
Page 3: ...3 5 5 4 12 10 7 9 6 11 12 8 9 9 13...
Page 4: ...4...
Page 5: ...5 3 1 2 max 500 ml max 17 US fl oz...
Page 6: ...6 5 mm 5 mm 1 3 2 5 5 4 2 6...
Page 7: ...7 1...
Page 8: ...8...
Page 9: ...9 12 mm 12 mm...
Page 10: ...10 100l 85l 75l 60l 50l 25l 100l 85l 75l 60l 50l 25l Memory Function...
Page 11: ...11 8 mm 1 2 3 1 2 4 2 2 3 1 1 1...
Page 12: ...12...
Page 13: ...13 5 mm 5 mm 82 mm...
Page 63: ...63 el el...
Page 64: ...64 el 10 PRCD PRCD PRCD Ax Zx RESET TEST...
Page 66: ...66 el FEIN ISO 8528 G2 10...
Page 67: ...67 el CFK PRCD PRCD 69 EN 62841...
Page 68: ...68 el FEIN 12 mm Memory Function 6 42 98 160 40 0 T 12 mm...