background image

OBID i-

scan

®

Installation

ID ISC.LRU3000

FEIG ELECTRONIC GmbH

Page 40 of 52

LRU3000 - Manual.doc

E N G L I S H

9.3 Digital 

Inputs 

X5

The optocouplers on Terminal X5 are galvanically isolated from the Reader electronics and must
therefore be externally supplied.

Fig. 11 Optocoupler pin-outs IN1 – IN5

Fig. 12 Internal and possible external wiring of the optocouplers

Optocoupler input (X5/1-5):
The input LED associated with the optocoupler is connected internally to a series resistor of 500 

.

For supply voltages of greater than 10V the input current must be limited to max. 20 mA by means
of an additional series resistor (see Table 11).

Table 11 shows the necessary external resistors for various external voltages U

ext

.

IN1+

IN2+

IN3+

IN4+

IN5+

OU

T1-C

OU

T2-C

REL1-NO

REL2-NO

REL3-NO

IN

1-

IN

2-

IN

3-

IN

4-

IN

5-

OUT1

-E

OUT2

-E

REL1-COM

REL2-COM

REL3-COM

+

IN1..5

Rint

Rext

-

Uext

Summary of Contents for OBID i-scan

Page 1: ...MONTAGE INSTALLATION preliminary public B 2010 03 01 M91001 0ed ID E doc OBID i scan ID ISC LRU3500 ID ISC LRU3000 deutsch english...

Page 2: ...OBID i scan Montage ID ISC LRU3000 FEIG ELECTRONIC GmbH Seite 2 von 52 LRU3000 Manual doc D E U T S C H deutsche Version ab Seite 3 english version from page 30 E N G L I S H...

Page 3: ...die in diesem Dokument be schriebenen Ger te enth lt FEIG ELECTRONIC GmbH weist ausdr cklich darauf hin dass die in diesem Dokument beschriebenen Ger te nicht f r den Einsatz mit oder in medizinische...

Page 4: ...ngsspannung ber PoE Power over Ethernet an X2 10 3 2 2 Ethernet Schnittstelle an X2 10 100Tbase 11 3 2 3 USB Schnittstelle X3 Host Kommunikation 12 3 2 4 USB Schnittstelle X4 WLAN 12 3 2 5 RS232 Schni...

Page 5: ...hrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs g ltigen Fassung F r eine ungeeignete falsche manuelle oder automatische Ein stellung von Parametern f r ein Ger t bzw ungeeignet...

Page 6: ...lt 1 2 Verf gbare Readertypen Folgende Reader sind z Z verf gbar Readertyp Beschreibung ID ISC LRU3500 EU Ger tevariante f r Europa mit PoE ID ISC LRU3000 EU Ger tevariante f r Europa ohne PoE ID ISC...

Page 7: ...T S C H 2 Montage Der Reader ist f r die Montage auf W nden auch im Freien konzipiert Zur Wandmontage befin den sich im Geh use vorgesehene L cher Ein Aufschrauben des Geh uses zur Montage ist nicht...

Page 8: ...baren Taster aufgelistet X2 X3 X4 X5 X6 T1 T2 X1 ANT1 ANT2 ANT3 ANT4 Bild 2 Anschluss bersicht Anschluss Beschreibung ANT 1 4 Anschluss der externen Antennen Eingangsimpedanz 50 X1 Versorgungsspannung...

Page 9: ...r Zerst rung des Steckers Klemme Beschreibung ANT 1 4 Anschluss der externen Antennen Eingangsimpedanz 50 Tabelle 5 Anschluss der externen Antennen Bild 3 Antennenanschl sse ANT1 4 und X1 f r die Vers...

Page 10: ...g ber die Signalverbindung 1 2 3 und 6 ist m glich Inline Power Bild 5 LAN und PoE Anschluss Hinweis Wenn der Reader ber PoE versorgt wird ist darauf zu achten das die maximale Aus gangsleistung des R...

Page 11: ...Bei einer strukturierten Verkabelung sollten mindestens Kabel der Kategorie CAT5 verwendet wer den Dies garantiert einen problemlosen Betrieb bei 10 Mbps oder 100 Mbps Vorraussetzung f r den Einsatz d...

Page 12: ...ngere Kabel sind nicht erlaubt 3 2 4 USB Schnittstelle X4 WLAN Der USB Anschluss kann f r ein standard WLAN Sticks genutzt werden Bild 7 USB Schnittstelle f r externes WLAN Interface Hinweis Es k nnen...

Page 13: ...c D E U T S C H 3 2 5 RS232 Schnittstelle X6 Der Anschluss der RS232 Schnittstelle erfolgt ber X6 Die bertragungsparameter k nnen per Softwareprotokoll konfiguriert werden Bild 8 Anschlussbelegung X6...

Page 14: ...485 A B RS485 B Tabelle 9 Pinbelegung RS485 Schnittstelle 3 2 6 1 Adresseinstellung RS485 f r Busbetrieb F r den Busbetrieb bietet der Reader die M glichkeit die ben tigte Busadresse per Software zu v...

Page 15: ...externe Beschaltung der Optokoppler Eing nge Optokopplereingang X5 IN1 5 Die Eingangs LED des Optokopplers ist intern mit einem Serienwiderstand von 500 beschaltet Bei Versorgungsspannungen gr er 10V...

Page 16: ...tigter externer Vorwiderstand Rext 5 V 10 V 11 V 15 V 270 16 V 20 V 560 21 V 24 V 820 Tabelle 10 Ben tigter externer Vorwiderstand Rext Hinweise Der Eingang ist f r eine maximale Eingangsspannung von...

Page 17: ...lemme X5 nach au en gef hrt Der Ausgang muss daher mit einer externen Spannung betrieben werden Bild 13 Optokoppler Ausg nge OUT1 2 Bild 14 Interne und m gliche externe Beschaltung der Optokoppler Aus...

Page 18: ...rf gung Bild 15 Pinbelegung Relaisausg nge REL1 3 Hinweise Jeder Relaisausgang ist f r max 24 V DC 2 A Dauerlast ausgelegt Der maximale Schaltstrom darf 1 A nicht berschreiten Der Relaisausgang ist nu...

Page 19: ...US BLINKT wechsel seitig Firmware Activation notwendig 0x17 Wrong Firmware 0x18 BLINKT gleichzeitig AUS BLINKT gleichzeitig RFC Hardware Error 0xF1 AUS BLINKT gleichzeitig BLINKT gleichzeitig Hardware...

Page 20: ...er eingeschaltet Blau Tag Detect ROT Antennen Impedanz Fehler 50Ohm oder 50Ohm Tabelle 11 Konfiguration der LED s 4 2 Reset Taster Bild 17 zeigt die Position der Reset Taster T1 und T2 Rechts neben de...

Page 21: ...und dem Antennengewinn in dBi Bei Verwendung einer zirkular polarisierte Antenne ist der Gewinn G dBic um 3 dB zu reduzieren Bei einer linearen Antenne ist der maximale linea re Gewinn G dBi anzusetze...

Page 22: ...8 7 dBic Werden Antennen mit einem gr eren Gewinn als 6dBi 9 dBic verwendet so m ssen bei der Berechnung der Ausgangsleistung des Readers der Antennengewinn und die Kabeld mpfung mit ber cksichtigt we...

Page 23: ...ANT U600 270 mit 6m Belden H155 Koaxialkabel Pout 36 dBm 10 5 dBic 3 dB 1 8 dB Pout 36 dBm 7 5 dBi 1 8 dB Pout 30 3 dBm Reader Configuration 1 0 Watt Aus Beispiel 2 l sst sich ableiten dass bei der V...

Page 24: ...D E U T S C H 5 Funkzulassungen 5 1 Europa CE Die Funkanlage entspricht bei bestimmungsgem er Verwendung den grundlegenden Anforde rungen des Artikels 3 und den brigen einschl gigen Bestimmungen der R...

Page 25: ...user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Co...

Page 26: ...ind 42 5 V DC bis 1Watt Ausgangsleistung Leistungsaufnahme max 35 VA Betriebsfrequenzen EU Reader FCC Reader 865 7 867 5MHz 4 Channel Plan 902 928MHz FCC CFR 47 Part 15 247 Ausgangsleistung 300 mW 4 W...

Page 27: ...ignalgeber optisch 8 LEDs zur Diagnose des Betriebszustandes Betriebssystem Linux 64MB RAM 256MB Flash Sonstiges Antikollisionsfunktion Echtzeituhr RSSI Umgebungsbedingungen Temperaturbereich Betrieb...

Page 28: ...subject of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitab...

Page 29: ...r Supply via PoE Power over Ethernet on X2 35 9 2 2 Ethernet Interface on X2 10 100Tbase 36 9 2 3 USB Interface X3 Host Communication 37 9 2 4 USB Interface X4 WLAN 37 9 2 5 RS232 Interface X6 38 9 2...

Page 30: ...tions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual...

Page 31: ...range 7 2 Available Reader types The following Readers are available Reader type Description ID ISC LRU3500 EU Device version for Europe with PoE ID ISC LRU3000 EU Device version for Europe without Po...

Page 32: ...nual doc E N G L I S H 8 Installation The Reader is designed for wall mount including outdoors Holes for mounting on a wall are provided in the housing It is not necessary to open the reader housing 2...

Page 33: ...sh buttons X2 X3 X4 X5 X6 T1 T2 X1 ANT1 ANT2 ANT3 ANT4 Fig 2 Connection Overview Connector Description ANT 1 4 Connection of the external antennas Impedance 50 X1 Power supply 24VDC 5 X2 10 100Tbase n...

Page 34: ...que will destroy the plug Terminal Description ANT 1 4 Connection for external antennas input impedance 50 Table 5 External antenna connection Fig 3 External antenna connection ANT1 4 and X1 for the p...

Page 35: ...ering Inline Power via the signal pin s 1 2 3 and 6 is possible Fig 5 LAN and PoE connection Note Take care if PoE is used the maximum reader output power of the reader must be limited to 1Watt It mus...

Page 36: ...ic Crossover Detection according to the 100BASE T Standard With structured cabling CAT 5 cables should be used This ensures a reliable operation at 10 Mbps or 100 Mbps The prerequisite for using TCP I...

Page 37: ...5m 20 inch It is not allowed to use longer cables 9 2 4 USB Interface X4 WLAN The USB Port X4 can be used for a standard WLAN USB Stick Fig 7 USB Interface for external WLAN interface Note It is possi...

Page 38: ...Manual doc E N G L I S H 9 2 5 RS232 Interface X6 The RS232 interface is connected on X6 The transmission parameters can be configured by means of software protocol Fig 8 RS232 interface pin outs on...

Page 39: ...terface pin outs on X6 RS485 Interface Abbreviation Description GND RS485 GND A RS485 A B RS485 B Table 10 RS485 interface pin outs 9 2 6 1 Address assignment of RS485 for bus operation For bus operat...

Page 40: ...external wiring of the optocouplers Optocoupler input X5 1 5 The input LED associated with the optocoupler is connected internally to a series resistor of 500 For supply voltages of greater than 10V t...

Page 41: ...voltage Uext Required external series resistor Rext 5 V 10 V 11 V 15 V 270 16 V 20 V 560 21 V 24 V 820 Table 11 Required external series resistor Rext Notes The input is configured for a maximum inpu...

Page 42: ...out any internal ancillary circuitry on Terminal X5 The output must therefore be powered by an external power supply Fig 13 Optocoupler Outputs OUT1 2 Fig 14 Internal and possible external wiring of t...

Page 43: ...elay output pin outs REL1 3 Notes The relay output is configured for max 24 V DC 2 A constant load The switching cur rent must not exceed 1A The relay output is intended for switching resistive loads...

Page 44: ...ternat ing OFF FLASH alternat ing Firmware Activation necessary 0x17 Wrong Firmware 0x18 FLASH synchro nous OFF FLASH synchro nous RFC Hardware Error 0xF1 OFF FLASH synchro nous FLASH synchro nous Har...

Page 45: ...Blue Tag Detect Red Antenna impedance error 50Ohm or 50Ohm Table 12 Configuration of the status LED s 10 2 Reset Push Button Fig 17 shows the position of the reset push button s T1 and T2 At the righ...

Page 46: ...t power Pout depends on the antenna gain in dBi and the at tenuation of the antenna cable If a circular polarized antenna is used the antenna gain dBic can be reduced by 3dB At a linear polarized ante...

Page 47: ...c are used If an antenna is used which gain is more then 6dBi 9dBic it is necessary to consider the antenna gain and the attenuation of the antenna cable to calculate the right output power If a circu...

Page 48: ...NT U600 270 and 6m Belden H155 Coaxial Cable Pout 36 dBm 10 5 dBic 3 dB 1 8 dB Pout 36 dBm 7 5 dBi 1 8 dB Pout 30 3 dBm Reader Configuration 1 0 Watt According to Example 2 it will only be necessary t...

Page 49: ...l doc E N G L I S H 11 Radio Approvals 11 1 1 Europe CE When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R TTE Direc...

Page 50: ...e user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver C...

Page 51: ...E Power over Ethernet min 42 5 V DC up to 1Watt reader output power Power consumption max 35 VA Operating Frequency EU Reader FCC Reader 865 7 867 5MHz 4 Channel Plan 902 928MHz FCC CFR 47 Part 15 247...

Page 52: ...Gen 2 EM4222 4444 optional 18000 6 B C optional Optical indicators 8 LEDs for operating status and diagnostics Ambient Temperature range Operating Storage 25 C to 50 C 13 F to 122 F 25 C to 85 C 13 F...