background image

APPLICATION-NOTE

preliminary

public (B)

2008-06-17

N61100-2e-ID-B.doc

OBID i-scan

®

Smartshelf Demo

Summary of Contents for OBID i-scan

Page 1: ...APPLICATION NOTE preliminary public B 2008 06 17 N61100 2e ID B doc OBID i scan Smartshelf Demo...

Page 2: ...tions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates...

Page 3: ...er issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this ma...

Page 4: ...equirements 7 3 1 1 Smartshelf Embedded Linux HF 7 3 1 2 Smartshelf Embedded Linux UHF 7 3 2 SmartShelfDemo Windows XP 2000 7 3 Installation 8 4 Settings 9 4 1 ISC ANT MUX ISC ANT UMUX Configuration 9...

Page 5: ...valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect applicat...

Page 6: ...es status messages if a transponder is detected or lost The application then sends a message to the client side Windows program called SmartShelfDemo which is the second pro gram SmartShelfDemo let s...

Page 7: ...er ID ISC LR2000 with ACC ACC Firmware V1 09 00 ID ISC ANT MUX Rev FE 553 3 with Firmware V1 05 Ethernet connection 3 1 2 Smartshelf Embedded Linux UHF Reader ID ISC LRU2000 with ACC ACC Firmware V1 0...

Page 8: ...ion After the firmware update the ACC reboots and the Smartshelf application is started 5 seconds later The green LED V6 signals a running ACC the orange LED V3 signals communication ac tions between...

Page 9: ...e ID B doc for ID ISC ANT MUX or M71100 xde ID B doc for ID ISC ANT UMUX 4 2 SmartShelfDemo After the first start of the program some settings for the smartshelf reader must be executed Press the butt...

Page 10: ...e HF Reader ID ISC LR2000 is used The combination of UHF Reader ID ISC LRU2000 and ID ISC ANT UMUX multiplexers can detect multiplexers and connected antennas automatically IP is the IP address of the...

Page 11: ...rules considering the antenna organisation when using the HF Reader ID ISC LR2000 There has to be a gapless structure It is not allowed to have a gap between two antennas General structure Until 8 ant...

Page 12: ...Page 12 of 17 N61100 2e ID B doc Example 12 antennas You need 2 multiplexers The first is directly connected to the reader the second MUX is conected to output 1 of the first multiplexer 7 antennas ar...

Page 13: ...2e ID B doc 4 3 2 Antenna organisation UHF Reader The combination of UHF Reader ID ISC LRU2000 and UHF Multiplexer ID ISC ANT UMUX has the ability to detect connected multiplexers and antennas automa...

Page 14: ...e number of the output of the multiplexer and the connection of that multiplexer in the structure The decimal places of the an tenna number describes the active outputs of the multiplexers on all 3 le...

Page 15: ...use for connection from other applications like ISOStart This has the advantage that the smartshelf activities are shortly interrupted for three seconds while the host command is executed Every next h...

Page 16: ...ocument version 1 0 document version reader name ID ISC LR2000 reader name ip address 192 168 3 205 ip address date 02 20 07 date time 15 45 28 time file header data tag uid 1234 event NEW event tag t...

Page 17: ...f 17 N61100 2e ID B doc The protocol which is generated and transmitted from SmartshelfDemo by pressing the button Save Settings OBID command set_config command config antennas 1 antennas threshold 1...