4.3. [0x82] Save Configuration
By the command Save Configuration each configuration block of the RAM can be stored in EEPROM.
Host
→
Reader
1
2
3
4
5-6
6
COM-ADR
[0x82]
CFG-ADR
CRC16
Host
←
Reader
1
2
3
4
5-6
6
COM-ADR
[0x82]
STATUS
1
CRC16
CFG-ADR
2
:
Bit:
7
6
5
4
3
2
1
0
Function
0
MODE
CFGn: Address of Configuration Block
CFGn:
memory-address of the required configuration block
MODE:
specifies one or all configuration blocks
b0
configuration block specified by CFGn
b1
all configuration blocks
Note:
•
To store RAM configuration after power down use
4.3. [0x82] Save Configuration
•
A save configuration to EEPROM with reserved configuration blocks will result in error
code 0x16.
1
see ANNEX B: Index of Status Bytes
2
see chapter 3. Configuration Parameters (CFG)