5.6. [0x69] RF Reset
The RF-field of the Reader antenna can be switched off for
t
rf
= 15 ms
by the command RF Reset.
Thus, all Transponders which are within the antenna field of the Reader will be reset to their base set-
ting.
Host
→
Reader
1
2
3
4,5
5
COM-ADR
[0x69]
CRC16
Host
←
Reader
1
2
3
4
5,6
6
COM-ADR
[0x69]
STATUS
1
CRC16
Notes:
•
After an RF Reset the Reader is not able to receive a new Transponder before expiration of t
rf
.
1