OBID i-scan
®
System-Manual
ID ISC.M02.M8-B
FEIG ELECTRONIC GmbH
Page 37 of 43
H90400-0e-ID-B.doc
DB-SIZE:
Number of bytes of one data block. This value depends on the specification of the Trans-
ponder manufacturer.
DB:
Data of the data block to be written to the Transponder. The required block size is defined by
DB-SIZE. The number of the expected bytes are DB-N * DB-SIZE.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
DB-ADR-E:
Block number where the error occurred.
Notes:
•
If an error occurred during a write command, the number of the block where the error oc-
curred will be send to host.
•
If an error occurred during a write command, the following blocks could not be written.
•
After an ISO Host command the RF power will be switched off automatically.