background image

OBID

 

 i-

scan

® 

HF

 

Installation 

ID ISC.LRM2500-A 

 

FEIG ELECTRONIC GmbH 

Page 5 of 30 

M10210-4e-ID-B.docx 

 

Performance Features of Reader Family ID ISC.LRM2500 

2.1  Performance Features 

The Reader has been developed for reading passive data carriers, so-

called „Smart Labels“, using 

an  operating frequency  of  13.56  MHz.  For  the  operation  it  is  necessary  to  connect  a  appropriate 

external antenna to the connector ANT1. 

 

2.2  Available Reader Types 

 

The following Reader type’s are currently available: 

Reader type 

Description 

ID ISC.LRM2500-A 

Module version with RS232/485- / USB- / LAN-Interface, USB-
Host und Embedded Linux 

ID ISC.LR2500-A 

Housing version with RS232/485- / USB- / LAN-Interface, USB-
Host und Embedded Linux 

ID ISC.LR2500-B 

Module version with RS232/485- / USB- / LAN-Interface 

Table 1: Available Reader types 

 

Summary of Contents for OBID i-scan ID ISC.LRM2500-A

Page 1: ...INSTALLATION final public B 2015 10 15 M10210 4e ID B docx ID ISC LRM2500 A Long Range Reader English...

Page 2: ...tion Since despite all our efforts errors may not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions...

Page 3: ...voltage 10 3 5 Fuse F1 11 3 6 X2 Optocoupler Inputs X2 IN1 IN2 IN3 12 3 7 Optocoupler outputs X2 OUT1 OUT2 15 3 8 Relay X2 REL1 REL2 REL3 16 3 9 Output 24V X2 24V GND 18 3 10 X8 External diagnostic LE...

Page 4: ...tomatically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should only be...

Page 5: ...of 13 56 MHz For the operation it is necessary to connect a appropriate external antenna to the connector ANT1 2 2 Available Reader Types The following Reader type s are currently available Reader typ...

Page 6: ...signed for installation on a heat sink Mounting is accomplished using the 4 5 mm holes located in each corner of the base plate see Figure 1 120 110 4 5 mm 160 155 80 4 5 mm 4 5 mm 5 4 5 mm 155 GND VD...

Page 7: ...esistance between the base plate and the heat sink as possible The use of heat sink compound is recommended If the antenna is properly tuned and there is sufficient air convection along the mounting p...

Page 8: ...EIG ELECTRONIC GmbH Page 8 of 30 M10210 4e ID B docx 3 2 Terminals Figure 2 shows the terminals and control elements of the ID ISC LRM2500 A V4 V3 V2 V1 V5 T1 X1 J2 J4 J1 J3 J6 J7 J5 X2 ANT1 X8 X6 F1...

Page 9: ...defined lengths For all antennas of the company FEIG ELECTRONICS GmbH and for all antennas which with the tuning boards e g ID ISC DAT ID ISC MAT b and ID ISC MAT s of FEIG ELECTRONICS GmbH is made t...

Page 10: ...oltage 24 V X6 Pin 2 GND Ground supply voltage Table 3 Pin outs for supply voltage on X6 GND VDC X8 X6 F1 1 2 Figure 4 Position of the connector X6 for the power supply Note Reversing the supply volta...

Page 11: ...ID B docx 3 5 Fuse F1 The reader have been protected with a SMD fuse 2 5A time lag Attention The 24V voltage for supplying the internal and external DC voltage on X2 for the dig ital inputs and output...

Page 12: ...2 NO REL1 NO 24V OUT1 E Figure 6 Optocoupler pin outs on terminal X2 The optocoupler on terminal strips X2 are galvanically isolated from the Reader electronics and must therefore be powered externall...

Page 13: ...820 J6 J5 24 V GND Figure 8 Possible internal power supply for the optocouplers The input LED for the optocouplers are internally connected to a series resistor of 1290 and are limited to an input cur...

Page 14: ...Table 4 Jumpers for inputs IN1 IN2 and IN3 Table 5 shows the required external series resistances for the various external voltages External voltage Uext Jumper J1 J3 J5 5 V 10 V ON 10 V 24 V OFF Tabl...

Page 15: ...be powered by an external power supply The digital outputs OUT1 and OUT2 can be used for the data clock interface OUT1 Clock OUT2 Data OUT1 E IN1 REL3 COM REL2 COM REL1 COM GND IN3 IN2 GND OUT2 E IN1...

Page 16: ...ore be externally supplied The external voltage may however be provided by the card using jumper J7 J8 J9 All 3 outputs are identical and may be configured individually IN1 REL3 COM REL2 COM REL1 COM...

Page 17: ...jumpers to the relay output Table 8 shows the jumper setting for the external voltage or internal VCC voltage Jumper Jumper J7 J8 J9 external voltage open Internal VCC voltage closed Table 8 Internal...

Page 18: ...500mA A possible current consumption via J2 J4 J6 or J7 J8 J9 must be factored in X2 IN1 REL3 COM REL2 COM REL1 COM GND IN3 IN2 GND OUT2 E IN1 OUT1 C GND IN3 IN2 OUT2 C REL3 NO REL2 NO REL1 NO 24V OU...

Page 19: ...ction same as internal LED V3 X8 Pin 4 V4 Anode ext Function same as internal LED V4 X8 Pin 5 V5 Anode ext Function same as internal LED V5 X8 Pin 6 GND Common GND Table 9 External LEDs pin outs exter...

Page 20: ...The RS232 interface is connected on X3 The transmission parameters can be configured by means of software protocol Figure 17 RS232 interface pin outs on X3 Kurzzeichen Description TxD RS232 Transmit...

Page 21: ...iation Description GND RS485 GND A RS485 A B RS485 B Table 11 RS485 interface pin outs With the Jumper J10 and J11 the Pull up and Pull down resistors can be activated if needed Jumper Closed Open J10...

Page 22: ...nterface can be not used for host communication 3 11 2 1 Address assignment of RS485 for bus operation For bus operation the Reader can be assigned the required bus address via software The address is...

Page 23: ...The USB host socket on the board is terminal X5 The pinout is standardized The data rate is re duced to 12 Mbit USB full speed It can be used for a standard WLAN USB Stick Figure 23 USB Host Interfac...

Page 24: ...AT 5 cables should be used This ensures a reliable operation at 10 Mbps or 100 Mbps The prerequisite for using TCP IP protocol is that each device has a unique address on the net work All Readers have...

Page 25: ...lashes alternately with V1 after a reset following a software update Flashes alternately with V1 in case of a data error when reading the parameters after a reset Flashes alternating with V1 and V5 fo...

Page 26: ...With the reset button T1 a manual CPU Reset can be performed With the push button T2 a complete configuration reset can be performed All reader parameters will be set to default For performing a reset...

Page 27: ...x 5 Radio Approvals 5 1 Europe CE When used according to regulation this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R TTE Guideline 1999...

Page 28: ...and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause har...

Page 29: ...pical 35 VA maximum 47VA depending on ext output circuitry Operating Frequency 13 56 MHz Transmit Power 2W 12 W 250 mW Step Software Modulation 10 30 Software configurable Antenna Connection SMA Jack...

Page 30: ...P I Code STM ISO Chips TI Tag it ISO18000 3M3 Upgrade Code required Optical Indicators 5 LEDs for Operating Status Diagnostics Ambient Temperature Range Operating Storage 20 C to 55 C 4 F to 131 F 25...

Reviews: