OBID
i-
scan
®
HF
Installation
ID ISC.LRM2500-A
FEIG ELECTRONIC GmbH
Page 24 of 30
M10210-4e-ID-B.docx
3.11.5 Ethernet-Interface on X1 (10/100 Base-T)
The Reader has an integrated 10 / 100 Base-T network port for an RJ-45. Connection is made on
X1 and has an automatic “Crossover Detection” according to the 1000 Base-T Standard.
With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps
or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address.
Network
Address
IP-Address
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
OFF
Table 14 Standard factory configuration of the Ethernet connection
Note:
The Reader TCP/IP interface has a DHCP option.
It is recommended to use a shielded twisted pair STP CAT5 cable.
X1
Figure 24: LAN interface for host communication