10. Start-Up
10.1. HF Communication Control Mode
In HF Communication Control Mode the multiplexer is controlled by protocols from the reader. No
additional cable between the reader and multiplexer is necessary. The protocols are described in
the system manual for the H30701-#e-ID-B.
The communication between the reader and multiplexer allows specific switching to a particular
outputs.
Figure 9 shows a simple application example with a multiplexer and four antennas. Use the
following DIP switch setting (see
9.2. DIP Switch S1
):
Table 7: DIP switch setting
1
2
3
4
5
6
7
8
ON
-
-
ON
-
-
-
-
Figure 9: Application example with four antennas in HF Communication Control Mode
Reader
OUT1-4
IN1
MUX
X1
50cm
Antennas
12-24VDC