OBID i-
scan
Installation
ID ISC.ANT.MUX
FEIG ELECTRONIC GmbH
Page 31 of 37
M30201-1de-ID-B.doc
E N
G
L I S H
9.2.3. Setting Single or Dual Mode in External Trigger Mode
In the external trigger mode the multiplexer can be used in single or dual mode. In single mode you
can only switch on one output. In dual mode you can switch on two outputs, one for IN1 and one
for IN2.
The dual mode is activated by turning on DIP switches 3 and 4. Otherwise the single mode is acti-
vated (see Table 5).
9.2.4. Setting Number of Outputs in External Trigger Mode
DIP switches 5-8 are used to set the number of outputs used in Single or Dual Mode:
Table 5: Setting number of outputs in Single and Dual Mode
DIP switch S1
Channels
1
2
3
4
5
6
7
8
Single-Mode
-
ON
-
-
-
-
-
ON Channel 1
-
ON
-
-
-
-
ON
-
Channel 1-2
-
ON
-
-
-
-
ON ON Channel 1-3
-
ON
-
-
-
ON
-
-
Channel 1-4
-
ON
-
-
-
ON
-
ON Channel 1-5
-
ON
-
-
-
ON ON
-
Channel 1-6
-
ON
-
-
-
ON ON ON Channel 1-7
-
ON
-
-
ON
-
-
-
Channel 1-8
Dual-Mode
-
ON ON ON
-
-
-
ON Channel 1+8
-
ON ON ON
-
-
ON
-
Channel 1+8, 2+7
-
ON ON ON
-
-
ON ON Channel 1+8, 2+7, 3+6
-
ON ON ON
-
ON
-
-
Channel 1+8, 2+7, 3+6, 4+5