IDENTIFICATION
Installation
ID ISC.ANT1520/680-A/-B
FEIG ELECTRONIC GmbH
Page 63 of 82
ID ISC.ANT1520680-A-B User
Manual_M61112-1e-ID-E-
060317.doc
7.2 Configuration and Test
To activate the People Counters the following settings has to be done.
Set additional the Jumpers JP10 and J11 of Reader ID ISC.LRM2500-B to configure the RS485
interface. (see also manual M01111-xde-ID-B , page 54 and 55). The Termination has to be acti-
vated via software in the reader configuration.
J11
VCC
J10
500
Ω
500
Ω
RS485 +
RS485 -
Fig. 24: Jumper settings RS485 Interface
7.2.1 Connecting several People Counter
When using several People Counters (up to 3), at one reader, you have to connect the terminal
boards of all used antennas with each other in parallel. For the connection you have to use 5 (6)
pin shielded, twisted-pair cable. Example: LiYCY (TP) 3x2x0,25 .
The cable (2.5m) is contents of antenna Type B
The Bus address of the People Counter will be defined by the antenna number it is installed in.
GPC1 in Antenna No.1 = Bus address No. 1
GPC2 in antenna No.4 = Bus address No. 2
GPC3 in antenna No.6 = Bus address No. 3
The Bus address will be set automatically after setup and configuration of the complete gate
system after a “System Reset” command in one of the Automatic Modes.
The successful detection of the connected Gate People Counter could be checked with command
“Get Reader Info”