IDENTIFICATION
Installation
ID ISC.ANT1520/680-A/-B
FEIG ELECTRONIC GmbH
Page 26 of 82
ID ISC.ANT1520680-A-B User
Manual_M61112-1e-ID-E-
060317.doc
6.3.2 Configuration of a Gate Antenna with Multiplexer
Connect the components as shown in Fig. 12 . Almost, all cable should be mounted already.
Normally, the antenna cable from antenna Type B has to be connected to OUT2 at the multiplexer
and the 24V DC power supply to X11 of the terminal board. Also a connection between
X13 GPC-out of the terminal board in Antenna Type A and X13 GPC-out of the terminal board in
Antenna Type B must be installed to supply the LED with power and RS485 Bus.
Fig. 12: Connecting the components for a gate consisting of two antennas, reader and multiplexer
LED1
1. Antenna
ID ISC.ANT.GPC
Gate People Counter
Radar Module 1
LCD-Display
X6
HF- Antenna A
135 cm
X1
8,55 m
IN
OUT 2
OUT 1
LED2
2. Antenna
DC Power
Supply24 V
X3
X2
Multiplexer
ID ISC.ANT.MUXM4
Long Range Reader
ID ISC.LRM2500-B
2. Antenna
ANT1