For example
:
When the rated power of the generator is PN
=
3.0KW, the altitude is 1000m, the ambient
temperature is 35
℃
, the relative humidity is 80%. Under these circumstances, the rated output of
the generator is P=PN×(C-0.02)=3.0×(0.77-0.02)=2.25KW.
Use of DC Power
DC socket only supplies for 12V automatic battery charging.
NOTICE
When using a DC socket to charge the battery, the person must be present to monitor the
battery voltage. If the battery voltage exceeds 16V, the charge must be stopped immediately,
otherwise the battery burns or explodes.
Start the generator as the above instruction.
Connect the charging cable to the generator DC socket and connect it to the battery terminal
WARNING
Connect the charging cable to the battery first, and then connect it to the generator.
Disassembly must start from the generator side, which prevents sparks start beside the
battery.
When connecting the charging cable to the car battery, disconnect the battery ground wire
first. Remove the cable and then connect to the ground wire on battery after charging is
complete. So that even if you make the battery terminal contact with the car frame by
accident, it can prevent short circuit or spark.
WARNING
Do not start the car when the generator is connected to the battery, otherwise it might damage
the generator.
Charging cable should be properly connected to the positive and negative terminals of the
battery, otherwise it will damage the generator or the battery.
WARNING
Charge should be properly ventilated, and away from fireworks, because the battery will
evaporate flammable gas.
The battery contains sulfuric acid (electrolyte). Contact with skin or eyes can cause burns.
Wear protective clothing and mask.
Electrolyte is toxic, if the electrolyte splashed on the skin, immediately rinse with water.
If the electrolyte splashes into the eyes, rinse immediately with water for 15 minutes and seek
medical care.
17