BE CAUTIOUS
If the main jet is designed for high altitude areas but is operating at low altitudes, it may cause
decreased output power, overheating, or serious engine damage due to thin air-fuel mix.
7. OPERATING THE GENERATOR
WARNING
When the output indicator on the control panel is ON, the generator is ready to use. The
generator should be grounded before connecting to any load. Please use cable to connect
the ground terminal on the generator control panel to an external ground source.
Please make sure the connected equipment is in good condition and turned off. Also make
sure that the total power of the appliance used does not exceed the max. power of the
generator.
Connect your equipment to the appropriate output socket on the generator control panel.
WARNING
In order to prevent electric shock caused by improper use, the generator should be
grounded. Connect a thick cable between the ground terminal of the generator and the
external ground source.
If the unit is used as a backup power source for a building, the connection of the generator to
its power system shall be carried out by a professional electrician and must comply with the
applicable laws and regulations. Otherwise, the power of the generator may impact on the
public circuit. If the power company employees or others touch the wire in the meantime, it
will lead to injury or even death; At the same time, due to the impact of electricity, the
generator may explode, burn or cause the building electricity equipment to fire.
BE CAUTIOUS
When the generator is running continuously, do not exceed the rated power. In other cases,
pay attention to the total power of the connected equipment.
Do not exceed the rated current of the socket.
Do not use the generator for purposes that it cannot achieve. Please also observe the
following requirements:
Do not parallel generators with unauthorized units or use unauthorized parallel power
cables or boxes.
Do not extend the exhaust pipe
If a longer cable is required, use a flexible cable for with rubber sleeve (the cable should
comply with IEC standards).
The length of the extension cable is limited, the cable of 2mm
2
is 60 meters long; the cable of
3mm
2
is 100 meters long.
The generator should be away from other electric wires or cables, such as: electricity
transmission network.
Note
When using AC power, you can use DC power at the same time. Please pay attention to the
sum of the power of AC and DC. It cannot exceed the rated power of the generator.
14