4. CONTROL SYSTEM                                                             

   

4.1 Engine oil alerting system(YELLOW) 

The engine oil  protection  system  will  stop  the  engine  automatically,  and the  engine  oil  indicating 
lights, while the oil in crankcase is under safe line

Fill the engine oil to the oil level, it can be restart 

again. 

 

If the engine oil alerting light flashes for few seconds, it means the oil capacity is insufficient. Refill 
the oil and restart the engine. 

4.2 Overload Indicating Light(RED) 

When the overload indicating light is on,   the generator detects that the output of the phase-side 
electrical equipment has been overloaded, causing the converter to overheat or the AC voltage to 
rise.  Then  the  AC  protector  works  and  stops  the  generator  to  protect  the  generator  and  the 
equipment  which  connects  with  it. The  AC  indicating  light(GREEN)  is  off,  but  overload  indicating 
light (RED)is on,engine will not stop working. 
While the overload light is on, and the generator has no output, please take following measures:   
9)  Turn off the connected electrical equipment and stop engine. 
10) Reduce the total power rate of connected electrical equipment within the rated output range.   
11) Check whether the cool air inlet is blocked by foreign matters and whether the relevant control 

parts are abnormal. If there is any problem, remove it immediately.   

12) Restart the engine after checking. 

 

When using the electrical equipment with high starting current(like compressor and sinking 
pump...),  the  overload  indicating  light  may  will  flash  for  few  seconds.  But  this  doesn’t 
belongs to troubles as aforementioned.   

4.3 AC Indicating Light (GREEN) 

The AC indicating light will be on while the engine starts and keep normal output. 

4.4 ECO Switch 

 “ON” 

While the ECO switch is on position of “ON”, the equipment will control rotating speed according to 
the connected load, so as to get good fuel oil consumption and low noise. 
 

 “OFF” 

While the ECO switch is on position of “OFF”, whether it connects with load, the engine also runs at 
a rated rotating speed.

 

 

Cause it needs heavy start current, ECO switch must be off while using compressor. 

4.5 Ground Terminal 

The  ground  terminal  is  connected  to  the  ground  wire  to  prevent  electric  shock.  The  generator 
should be connected to ground while the electrical equipment connecting to ground. 

 

 

Summary of Contents for FG2000i-B

Page 1: ...ORIGINA LINSTRUCTIONS EN GASOLINE INVERTER GENERATOR LOW VOLTAGE GENERATING SET FG2000i B USER GUIDE WARNING Read the instructions carefully before using this machine...

Page 2: ...NTROL SYSTEM 9 5 PREPARATION 10 6 GENERATOR USE 13 7 STARTING THE ENGINE 15 8 MAINTENANCE 18 9 TRANSPORTING STORING 21 10 TROUBLESHOOTING 23 11 ELECTRICAL DIAGRAMS 24 12 TECHNICAL SPECIFICATIONS 25 13...

Page 3: ...such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what you are doing and show good sense when you use the generator Do not use if you are tired or unde...

Page 4: ...if you get drops of fuel in your eyes see a doctor immediately If a certain quantity of fuel is split on your skin or clothing wash or change your clothes Always stop the motor of the generator when...

Page 5: ...nerating sets for use by laymen Protect children by keeping them at a safe distance from the generating set Fuel is combustible and easily ignited Do not refuel during operation Do not refuel while sm...

Page 6: ...2 SAFETY WARNING LABEL Safety warning label Guaranteed sound power level...

Page 7: ...3 COMPONENTS IDENTIFICATION 3 1 Components Feature...

Page 8: ...different configuration Please note that subject to change without prior notice 1 AC reset 5 ECO switch 2 Low oil indicator Yellow 6 AC socket 230V 3 Overload Indicating Light Red 7 Ground terminal 4...

Page 9: ...gine 10 Reduce the total power rate of connected electrical equipment within the rated output range 11 Check whether the cool air inlet is blocked by foreign matters and whether the relevant control p...

Page 10: ...asoline storage area Gasoline shall not overflow the tank the oil level is lower than the red oil level indicator After refueling tighten the tank cover After refueling dry the remaining gasoline with...

Page 11: ...dirt or dust from falling into the oil When adding oil wipe the area around the refueling opening Do not mix different specifications of oil to prevent negative effects on oil performance Running the...

Page 12: ...e it Take out the air filter element If necessary clean or replace the filter element The engine is not allowed to run without an air filter element otherwise the dirt will enter the engine through th...

Page 13: ...ician or someone familiar with the electricity After connecting the load to the generator carefully check whether the electrical connection is safe and reliable If there is incorrect electrical connec...

Page 14: ...ion at altitudes above 1000 meters The performance of a gasoline engine can be improved by replacing a slightly smaller main nozzle on the carburetor or by adjusting the adjustment screw If you often...

Page 15: ...nds before starting so that gasoline can enter the engine carburetor It is strictly forbidden to use in indoor and closed environment 1 The tank cap switch rotates to ON position Note When the generat...

Page 16: ...gure Pay attention to pull the starting handle the pull angle should not be too large so as not to wear the housing shell Do not allow the starting handle to rebound and retract automatically to avoid...

Page 17: ...3 Turn the engine switch to OFF 4 The tank cap switch rotates to OFF position To stop the engine in an emergency turn the Engine Switch to the OFF position Be sure the Fuel tank cap switch and Engine...

Page 18: ...ave the proper tools data and technical skills If you often work at high temperature or high load you should replace the engine oil every 10 hours If you work in dusty or harsh environments clean the...

Page 19: ...4 Refill the recommended oil and check the oil level 5 Re install the air filter maintenance cover and tighten the dipstick...

Page 20: ...apid wear and tear of the gasoline engine 1 Loosen the maintenance cover screws and remove the maintenance cover 2 Snap open the Air Cleaner cover and remove it 3 Take out the Air Cleaner element and...

Page 21: ...condition Avoid exposing directly in the sunshine When the generator place in the enclosed transport vehicle for a long time The high temperature inside the vehicle could cause fuel to vaporize resul...

Page 22: ...ion and tighten the drain screw of carburetor 5 Re install the Spark Plug cap 9 3Change the engine oil 9 4Remove the Spark Plug and fill 10 20ml engine oil into the cylinder Crank the engine several t...

Page 23: ...10 TROUBLESHOOTING...

Page 24: ...11 ELECTRICAL DIAGRAMS...

Page 25: ...35 L Measured sound power level LwA 87 44dB A K 1 13dB A Guaranteed sound power level 89 dB A Generator Fuel tank Capacity L 4 L Frequency Hz 50Hz Phase Single Rated Voltage V 230V Rated Power kW COP...

Page 26: ...the following European directives EMC Directive 2014 30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies w...

Page 27: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France MADE IN PRC 2023...

Reviews: