4. CONTROL SYSTEM
4.1 Engine oil alerting system(YELLOW)
The engine oil protection system will stop the engine automatically, and the engine oil indicating
lights, while the oil in crankcase is under safe line
;
Fill the engine oil to the oil level, it can be restart
again.
If the engine oil alerting light flashes for few seconds, it means the oil capacity is insufficient. Refill
the oil and restart the engine.
4.2 Overload Indicating Light(RED)
When the overload indicating light is on, the generator detects that the output of the phase-side
electrical equipment has been overloaded, causing the converter to overheat or the AC voltage to
rise. Then the AC protector works and stops the generator to protect the generator and the
equipment which connects with it. The AC indicating light(GREEN) is off, but overload indicating
light (RED)is on,engine will not stop working.
While the overload light is on, and the generator has no output, please take following measures:
9) Turn off the connected electrical equipment and stop engine.
10) Reduce the total power rate of connected electrical equipment within the rated output range.
11) Check whether the cool air inlet is blocked by foreign matters and whether the relevant control
parts are abnormal. If there is any problem, remove it immediately.
12) Restart the engine after checking.
When using the electrical equipment with high starting current(like compressor and sinking
pump...), the overload indicating light may will flash for few seconds. But this doesn’t
belongs to troubles as aforementioned.
4.3 AC Indicating Light (GREEN)
The AC indicating light will be on while the engine starts and keep normal output.
4.4 ECO Switch
①
“ON”
While the ECO switch is on position of “ON”, the equipment will control rotating speed according to
the connected load, so as to get good fuel oil consumption and low noise.
②
“OFF”
While the ECO switch is on position of “OFF”, whether it connects with load, the engine also runs at
a rated rotating speed.
Cause it needs heavy start current, ECO switch must be off while using compressor.
4.5 Ground Terminal
The ground terminal is connected to the ground wire to prevent electric shock. The generator
should be connected to ground while the electrical equipment connecting to ground.
Summary of Contents for FG2000i-B
Page 6: ...2 SAFETY WARNING LABEL Safety warning label Guaranteed sound power level...
Page 7: ...3 COMPONENTS IDENTIFICATION 3 1 Components Feature...
Page 23: ...10 TROUBLESHOOTING...
Page 24: ...11 ELECTRICAL DIAGRAMS...
Page 27: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France MADE IN PRC 2023...