Clean the components of the air filter periodically, and replace the air filter when necessary. 

 

Remove any electrical equipment that is plugged in before starting or stopping the generator. 

 

Before transporting the generator, you must empty the fuel tank. 

 

Maintenance and repair of the generator must be carried out by a qualified technician from an 
authorized after-sales service centre. 

 

WARNING:

   

when  you  start  the  generator  with  the  cord,  watch  out  for  sudden  changes  in  the  rotation  of  the 
motor!!! Risk of wounding!!! Never cover the generator when it is running. The cut-out mounted on 
the  generator  has  the  aim  of  reducing  the  risk  of  electric  shock.  If  it  needs  to  be  replaced  with 
another cut-out, the latter must correspond to the technical specifications of the generator. Due to 
important  mechanical  constraints,  it  is  necessary  to  use  a  flexible  sheathed  cable  with  a  strong 
rubber protective layer (conforming to IEC 245-4) or a similar cable. If using an electrical extension 
cable, the total length of the extension must not exceed 60m when the section of the wire is 1.5mm

2

 

and must not exceed 100m when the section of the wire is 2.5mm

2

 

SECURITY MEASURES WHEN FILLING THE FUEL TANK 

 

The fuel is extremely flammable and poisonous. 

 

This generator only uses petrol (gasoline); any other kind of fuel will damage the motor. 

 

Do  not  overfill  the  tank  with  petrol  to  avoid  spilling.  If  you  notice  a  spill,  it  must  be  wiped  up 
completely with a dry cloth before starting the motor. 

 

If you swallow fuel by mistake, if you inhale fuel vapors or if you get drops of fuel in your eyes, 
see a doctor immediately. If a certain quantity of fuel is split on your skin or clothing, wash or 
change your clothes. 

 

Always stop the motor of the generator when filling it with fuel.   

 

Never fill the fuel tank while smoking or near a naked flame. 

 

Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling 
with fuel. 

 

Keep the fuel in an appropriate recipient and sheltered from any sources of fire. 

 

Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has 
built up inside the tank. Wipe up any drops of petrol that have spilled before starting the motor. 

 

To prevent fire, move the generator at least 4 meters away from the area for filling with fuel. 

 

Make sure that the fuel cap is tightly closed before starting. 

 

Do not keep petrol in the tank for a long time. 

 

While  using  or  transporting  the  generator,  make  sure  you  keep  the  generator  upright, 

otherwise the fuel may escape from the carburettor or the fuel tank. 

ELECTRICAL SAFETY 

Before each use ensure that the load to be connected does not exceed the power of the current 
produced by the generator. 

To avoid electric shock, you must follow the following instructions: 

 

Do not touch the generator with wet hands. 

 

Do not run the generator under rain or snow. 

 

Do not run the generator near water. 

 

Connect the generator to earth. Use a sufficiently thick conductor for the earth wire. 

 

Do not operate the generator in parallel with another generator. 

 

If using electrical extensions, make sure that they are sufficiently thick to transport the current 
and that they are used correctly. 

The  connection  of  a  generator  used  for  auxiliary  power  to  the  electrical  installation  of  a 

Summary of Contents for FG2000i-B

Page 1: ...ORIGINA LINSTRUCTIONS EN GASOLINE INVERTER GENERATOR LOW VOLTAGE GENERATING SET FG2000i B USER GUIDE WARNING Read the instructions carefully before using this machine...

Page 2: ...NTROL SYSTEM 9 5 PREPARATION 10 6 GENERATOR USE 13 7 STARTING THE ENGINE 15 8 MAINTENANCE 18 9 TRANSPORTING STORING 21 10 TROUBLESHOOTING 23 11 ELECTRICAL DIAGRAMS 24 12 TECHNICAL SPECIFICATIONS 25 13...

Page 3: ...such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what you are doing and show good sense when you use the generator Do not use if you are tired or unde...

Page 4: ...if you get drops of fuel in your eyes see a doctor immediately If a certain quantity of fuel is split on your skin or clothing wash or change your clothes Always stop the motor of the generator when...

Page 5: ...nerating sets for use by laymen Protect children by keeping them at a safe distance from the generating set Fuel is combustible and easily ignited Do not refuel during operation Do not refuel while sm...

Page 6: ...2 SAFETY WARNING LABEL Safety warning label Guaranteed sound power level...

Page 7: ...3 COMPONENTS IDENTIFICATION 3 1 Components Feature...

Page 8: ...different configuration Please note that subject to change without prior notice 1 AC reset 5 ECO switch 2 Low oil indicator Yellow 6 AC socket 230V 3 Overload Indicating Light Red 7 Ground terminal 4...

Page 9: ...gine 10 Reduce the total power rate of connected electrical equipment within the rated output range 11 Check whether the cool air inlet is blocked by foreign matters and whether the relevant control p...

Page 10: ...asoline storage area Gasoline shall not overflow the tank the oil level is lower than the red oil level indicator After refueling tighten the tank cover After refueling dry the remaining gasoline with...

Page 11: ...dirt or dust from falling into the oil When adding oil wipe the area around the refueling opening Do not mix different specifications of oil to prevent negative effects on oil performance Running the...

Page 12: ...e it Take out the air filter element If necessary clean or replace the filter element The engine is not allowed to run without an air filter element otherwise the dirt will enter the engine through th...

Page 13: ...ician or someone familiar with the electricity After connecting the load to the generator carefully check whether the electrical connection is safe and reliable If there is incorrect electrical connec...

Page 14: ...ion at altitudes above 1000 meters The performance of a gasoline engine can be improved by replacing a slightly smaller main nozzle on the carburetor or by adjusting the adjustment screw If you often...

Page 15: ...nds before starting so that gasoline can enter the engine carburetor It is strictly forbidden to use in indoor and closed environment 1 The tank cap switch rotates to ON position Note When the generat...

Page 16: ...gure Pay attention to pull the starting handle the pull angle should not be too large so as not to wear the housing shell Do not allow the starting handle to rebound and retract automatically to avoid...

Page 17: ...3 Turn the engine switch to OFF 4 The tank cap switch rotates to OFF position To stop the engine in an emergency turn the Engine Switch to the OFF position Be sure the Fuel tank cap switch and Engine...

Page 18: ...ave the proper tools data and technical skills If you often work at high temperature or high load you should replace the engine oil every 10 hours If you work in dusty or harsh environments clean the...

Page 19: ...4 Refill the recommended oil and check the oil level 5 Re install the air filter maintenance cover and tighten the dipstick...

Page 20: ...apid wear and tear of the gasoline engine 1 Loosen the maintenance cover screws and remove the maintenance cover 2 Snap open the Air Cleaner cover and remove it 3 Take out the Air Cleaner element and...

Page 21: ...condition Avoid exposing directly in the sunshine When the generator place in the enclosed transport vehicle for a long time The high temperature inside the vehicle could cause fuel to vaporize resul...

Page 22: ...ion and tighten the drain screw of carburetor 5 Re install the Spark Plug cap 9 3Change the engine oil 9 4Remove the Spark Plug and fill 10 20ml engine oil into the cylinder Crank the engine several t...

Page 23: ...10 TROUBLESHOOTING...

Page 24: ...11 ELECTRICAL DIAGRAMS...

Page 25: ...35 L Measured sound power level LwA 87 44dB A K 1 13dB A Guaranteed sound power level 89 dB A Generator Fuel tank Capacity L 4 L Frequency Hz 50Hz Phase Single Rated Voltage V 230V Rated Power kW COP...

Page 26: ...the following European directives EMC Directive 2014 30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies w...

Page 27: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France MADE IN PRC 2023...