Configuring the Light
XStream
®
Model XSMxx-xxx
Federal Signal
www.fedsig.com
Color Designations
The color codes in the model number correspond to the colors listed below:
For example Model XSM1-BRW
COLOR1 =
B
(Blue)
COLOR2 =
R
(Red)
COLOR3 =
W
(White)
Code List:
B
= Blue,
R
= Red,
W
= White,
A
= Amber,
G
= Green
Configuring the Light
Two recessed switches in the side of the housing enable you to configure how the
light operates. Switch
S1
displays and sets the flash pattern. Switch
S2
displays and
sets the color mode. You can also configure the light for Low Power Mode. A small
precision screwdriver or paperclip is required to access the switches. See Figure 3.
Figure 3 Recessed switch locations in housing
S1 Selector Switch
For Flash Pattern
S2 Selector
Switch For Color
To select an action in Table 3, press
S1
for the duration listed in the
Seconds
column.
To confirm your selection, the LEDs respond as shown in the table. For a list of flash
patterns, see Table 4.
Table 3 S1 Flash Pattern Selection Switch
Seconds
COLOR 1 LED
Response
Action
0–1
Bright
Next Pattern
1–3
Dim
Previous Pattern
3–5
Low
*Low Power
5+
Bright
Reset to Pattern 1
*Low Power Mode is disabled when the operator switches to another flash pattern.