Strobe Light Installation
The optional strobe light accessories enable the TAR to provide warning
to the hearing impaired and users in high ambient noise areas. To use a
strobe light accessory, an IO model of the Informer is required to provide
the necessary relay output for controlling the strobe. The strobe light
accessory also requires a second 120 VAC, 60 Hz outlet.
This accessory must be installed per local and national
electrical codes by a qualified electrician.
3-6-1 Model FB2PST-012-024C Strobe Light Accessory Installation
Install the strobe on the wall near the TAR
at least 24” below the ceiling
per
instructions provided with the unit.
Install the model PS250 power
supply on the wall near the strobe and TAR per instructions provided with
the unit. Make electrical connections to the strobe, power supply and TAR
as shown in the following diagram. The connection between the TAR and
the strobe requires an 18 AWG two-wire cable with 5mm (3/16”) stripped
wire on the TAR end and 5/16” stripped wire on the other. Make all other
connections before connecting power. Connect the batteries first, and
then AC power, after all other connections have been made.
Refer to the wiring diagram on the following page.
3-4