background image

Kramer Electronics, Ltd. 

 
 

 

 

 

 

 
 
 
 

 

USER MANUAL 

 

 

Models: 

PT-110, 

XGA Line Transmitter

 

WP-110,

 XGA Line Transmitter 

PT-120, 

XGA Line Receiver

 

TP-120, 

XGA Line Receiver

 

 

Summary of Contents for PT-110

Page 1: ...Kramer Electronics Ltd USER MANUAL Models PT 110 XGA Line Transmitter WP 110 XGA Line Transmitter PT 120 XGA Line Receiver TP 120 XGA Line Receiver ...

Page 2: ...eceiver 8 5 Using the XGA Line Transmitter s Receiver 9 5 1 Installing the WP 110 XGA Line Transmitter 11 5 2 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors 11 6 Technical Specifications 12 Figures Figure 1 PT 110 XGA Line Transmitter 5 Figure 2 WP 110 XGA Line Transmitter 6 Figure 3 PT 120 XGA Line Receiver 7 Figure 4 TP 120 XGA Line Receiver 8 Figure 5 XGA to Twisted Pair Transmitter and Rec...

Page 3: ...ty and stores The package includes the following items PT 110 XGA Line Transmitter or WP 110 XGA Line Transmitter or PT 120 XGA Line Receiver or TP 120 XGA Line Receiver Power adapter 12V DC Input and this user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this use...

Page 4: ...e Kramer Pico TOOLS PT 110 is an XGA line transmitter that receives an XGA signal and transmits it over a CAT 5 cable to the PT 120 or TP 120 receiver In particular the PT 110 Has a resolution of up to UXGA Can use the simplest UTP CAT 5 cables and performs even better with higher quality cables Has the Power Connect feature Is 12V DC fed 3 2 WP 110 XGA Line Transmitter The Kramer Wall Plate WP 11...

Page 5: ...Q and level controls Has the power connect feature Is 12V DC fed 3 5 About the Power Connect Feature The Power Connect feature applies as long as the cable can carry power This feature is available when using STP cable and the distance does not exceed 50m on standard CAT 5 cable For longer distances heavy gauge cable should be used1 For units which are connected via RJ 45 connectors make sure that...

Page 6: ... be preferred for long range applications the UTP cable should be installed far away from electric cables motors and so on which are prone to create electrical interference However since the use of UTP cable might cause inconformity to electromagnetic standards Kramer does not commit to meeting the standard with UTP cable 3 7 Achieving the Best Performance To achieve the best performance Use only ...

Page 7: ...connector for powering the unit 2 XGA INPUT 15 pin HD F Connector Connect to the XGA source 3 LINE OUT RJ 45 Connector Connects to the LINE IN RJ 45 connector on the PT 120 or TP 120 XGA Line Receiver1 4 VS Switch Slide down to set the V SYNC to negative polarity NEGATIVE slide up2 to set the V SYNC to positive polarity NORM 5 HS Switch Slide down to set the H SYNC to negative polarity NEGATIVE sl...

Page 8: ...iver 6 4 2 Your WP 110 XGA Line Transmitter The WP 110 is available in three versions one for the US one for Belgium and Germany and one for the UK and most of Europe1 as Figure 2 and Table 2 define Figure 2 WP 110 XGA Line Transmitter 1 Excluding Belgium and Germany ...

Page 9: ...arity2 slide the switch to the right NORM to retain the polarity 5 LINE OUT RJ 45 Connector Connects to the LINE IN RJ 45 connector on the PT 120 or TP 120 XGA Line Receiver4 6 POWER SUPPLY GND PIN Connect to the Ground 12V DC PIN Connect to the connector for powering the unit 4 3 Your PT 120 XGA Line Receiver This section describes the PT 120 XGA Line Receiver Figure 3 and Table 3 define the tops...

Page 10: ...of the TP 120 XGA Line Receiver Figure 4 TP 120 XGA Line Receiver Table 4 TP 120 XGA Line Receiver Features Feature Function 1 12V DC 12V DC connector for powering the unit 2 XGA OUT 15 pin HD F Connector Connect to the XGA acceptor 3 LINE IN RJ 45 Connector Connects to the LINE OUT RJ 45 connector on the PT 110 or WP 110 XGA Line Receiver3 4 EQ 2 Trimmer Adjusts1 the cable compensation equalizati...

Page 11: ...e LINE IN RJ 45 connector on the TP 120 via UTP cabling with a range of more than 300ft 100m 4 On both2 the PT 110 and the TP 120 connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity The signal from the XGA source is transmitted via CAT 5 cable decoded and converted at the XGA OUT 15 pin HD F connector to the XGA acceptor 5 On the TP 120 adjust3 the...

Page 12: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Using the XGA Line Transmitter s Receiver 10 Figure 5 XGA to Twisted Pair Transmitter and Receiver System via UTP Cable ...

Page 13: ...y using the screws 4 Connect the XGA source to the XGA IN 15 pin HD F connector 5 2 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors Table 5 and Figure 6 define the CAT 5 PINOUT using a straight pin to pin cable with RJ 45 connectors Table 5 CAT 5 PINOUT Figure 6 CAT 5 PINOUT EIA TIA 568A EIA TIA 568B PIN Wire Color PIN Wire Color 1 Green White 1 Orange White 2 Green 2 Orange 3 Orange White 3 Gr...

Page 14: ...CTOR2 0 05 S N RATIO2 69dB worst case CONTROLS 7 7dB to 3 1dB 130m level 0dB to 25dB EQ 50MHz 7 5dB to 4 4dB 130m level 0dB to 33dBm 130m EQ 50MHz COUPLING AC AC DC AC POWERSOURCE 12V DC 60mA 12V DC 60mA 12V DC 175mA 12V DC 160mA DIMENSIONS 6cmx6 5cmx2 5cm 2 36 x2 56 x1 W D H USA 6 9cm x 3 8cm x 11 4cm 2 72 x1 5 x4 5 W D H 6cm x6 5cm x2 5cm 2 36 x2 56 x1 W D H 12cm x7 5cm x 2 5cm 4 7 x 0 98 x 2 95...

Page 15: ...ature ii Product modification orfailure to followinstructions supplied with theproduct iii Repairorattemptedrepair by anyonenot authorized byKramer iv Anyshipment of theproduct claims must bepresentedtothecarrier v Removalorinstallationof theproduct vi Anyother cause whichdoes not relateto aproduct defect vii Cartons equipment enclosures cables oraccessories usedinconjunctionwith theproduct 1 Remo...

Page 16: ... For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the unit from the power supply before opening servicing ...

Reviews: