Federal Signal Corporation QuadraFlare QL64Z3V-LI Installation Manual Download Page 4

2

  

  Q

uadra

F

lare

 Warning Lights

•   A  light  system  is  a  high  current  system.  For  the  system  to  function 

properly, a separate negative (–) connection and positive (+) connec

-

tion must be made. All negative connections should be connected to the 
negative battery terminal and a suitable fuse should be installed on the 
positive battery terminal connection as close to the battery as possible. 
Ensure that all wires and fuses are rated correctly to handle the device 
and system amperage requirements.

•   Never attempt to install aftermarket equipment that connects to the ve

-

hicle wiring without reviewing a vehicle wiring diagram available from 
the vehicle manufacturer. Ensure that your installation will not affect 
vehicle  operation  or  mandated  safety  functions  or  circuits.  Always 
check the vehicle for proper operation after installation.

•   The lighting system components, especially light bulbs, strobe tubes, 

LEDs, and the outer housing, get hot during operation. Be sure to dis

-

connect power to the system and allow the system to cool down before 
handling any components of the system.

•   Halogen light bulbs and strobe tubes are pressurized and if broken, can 

burst and result in flying glass. Always wear gloves and eye protection 
when handling these components.

•   Do not mount a radio antenna within 18 inches (45.7 cm) of the light

-

ing system. Placing the antenna too close to the lighting system could 
cause the lighting system to malfunction or be damaged by strong radio 
fields. Mounting the antenna too close to the lighting system may also 
cause the radio noise emitted from the lighting system to interfere with 
the reception of the radio transmitter and reduce radio reception.

•   Do not attempt to wash any unsealed electrical device while it is con

-

nected to its power source.

During Installation and Service

•   DO NOT get metal shavings inside the product. Metal shavings in the 

product can cause the system to fail. If drilling must be done near the 
unit, place an ESD-approved cover over the unit. Inspect the unit after 
mounting to be sure there are no shavings present in or near the unit.

•   DO NOT connect this system to the vehicle battery until ALL other 

electrical connections are made, mounting of all components is com

-

plete, and you have verified that no shorts exist. If the wiring is shorted 
to the vehicle body or frame, high current conductors can cause hazard

-

ous sparks resulting in electrical fires or flying molten metal.

•   DO NOT install equipment or route wiring (or the plug-in cord) in the 

deployment path of an airbag.

Summary of Contents for QuadraFlare QL64Z3V-LI

Page 1: ...Installation Manual 2562429B REV B 1109 Printed in U S A QuadraFlare Models QL64Z3V LI and QL64Z3V RI...

Page 2: ...l 1 Safety Message to Operators of Warning Light Equipment 4 Product Overview 6 Unpacking the Product 6 Mounting the QuadraFlare Lights 6 Making Electrical Connections 7 Completing the Installation 8...

Page 3: ...o this lighting product at a close range or per manent damage to your eyesight may occur Do not install the light system in an area that would block impair or blind the driver s vision Ensure that the...

Page 4: ...n flying glass Always wear gloves and eye protection when handling these components Do not mount a radio antenna within 18 inches 45 7 cm of the light ing system Placing the antenna too close to the l...

Page 5: ...to the manual packed with the lighting system for proper electri cal connections additional precautions and information Because vehicle roof construction and driving conditions vary do not drive a ve...

Page 6: ...the product Failure to follow all safety precautions and instructions may result in property damage serious injury or death to you or others RETAIN AND REFER TO THIS MESSAGE Safety Message to Operator...

Page 7: ...ting is for temporary applications only The unit should be removed from the window and stored securely when not in use Temperature changes and sunlight can cause suction cups to lose holding power Per...

Page 8: ...connector for every Quadra Flare light The male Packard connectors are user supplied Table 1 Mounting hardware Qty Description Part No 4 10 x 3 4 Screw S S 7011182 12 Mounting the QuadraFlare Lights A...

Page 9: ...the area into which you plan to drill to ensure you do not damage vehicle components while drilling All drilled holes should be deburred and all sharp edges should be smoothed All wires going through...

Page 10: ...cause crazing such as strong de tergents solvents or petroleum products If crazing of lenses does occur the reliability of light for emergency signaling purposes may be reduced until lenses are repla...

Page 11: ...Warning Lights 5 75 14 38 4 50 21 4 PLACES MOUNTING GASKET VEHICLE BODY 1 50 3 PLACES 10 X 3 4 SCREW 4 290A6150 3 0 10 X 3 4 SCREW 4 21 6 6 9 MOUNTING GASKET VEHICLE BODY Figure 1 Vertical and horizo...

Page 12: ...ents to Service Department Federal Signal Corporation Phone 1 800 433 9132 Fax 1 800 343 9706 Email empserviceinfo fedsig com 7 am to 5 pm Monday through Friday Central Time Table 1 Replacement parts...

Page 13: ...2645 Federal Signal Drive University Park IL 60484 3167 Tel 800 264 3578 Fax 800 682 8022 www fedsig com 2009 Federal Signal Corporation...